CONTROL 77.6 INPUTS - OUTPUTSGr Id FunctionJ1 G-G0 24 Vdc or 24 Vacpower supply (0 on G0) .J2J3J4J5J6J7B1B2B3B4B5Y1Y2Y3Y4ID1ID2ID3ID4ID5ID6ID7ID8B6B7B8ID9ID10ID11ID12BT300 source temperature probeBT110 input temperature probe of the condenserBT107 input temperature probe heat utilisationBT108 output temperature probe heat utilisationYv102 modulating valve control output (3-way condenser)Yv202 modulating valve control output (3-way evaporator)206 bypass pump control output evaporator sideYv105 modulating valve control output (bypass onthe condenser)106 pump thermal (bypass heat utilisation) (opened=> alarm)FreeFreeFreeYv103 valve stop (source valve condenser side)(closed => valve off)Yv203 valve stop (source valve condenser side)(closed => valve off)Yv104 valve stop (source valve evaporator side)(closed => valve off)Yv204 valve stop (source valve evaporator side)(closed => valve off)FreeFreeFree101a pump thermal (condenser) (opened => alarmpump)201a pump thermal (evaporator) (opened => alarmpump)101b pump thermal (condenser) (opened => alarmpump)201b pump thermal (evaporator) (opened => alarmpump)J8ID13ID14206 bypass pump thermal of the evaporator (opened=> alarm pump) (delay sw 3 sec)Flx300 flow switch input (closed present flow)J9 - Telephonic connectorJ10 - Telephonic connector for unit terminal connectionJ11 - Connectors for the unit PLan net connectionJ12J13NO1NO2NO3NO4NO5NO6Control for the source activation request (closedactive request)Presence of unit cumulative alarm (closed presentalarms)FreeJ14 NO7 Free201b pump control (evaporator)106 pump control (bypass heat utilisation)Remote On/Off control Talk electronicsJ15 NO8 201a pump control (evaporator)J16NO9NO10NO11Control of the simultaneous Yv103, Yv104 valveopening source condenser sideControl of the simultaneous Yv103, Yv104 valveclosing source condenser sideFreeJ17 NO12 101b pump control (condenser)J18 NO13 206 pump control (bypass cool utilisation)J19J20J21J22ID15ID16Y5Y6B9B10ID17ID18NO14NO15NO16NO17NO18FreeFreeFreeFreeBT207 input temperature probe cool utilisationBT208 output temperature probe cool utilisationFreeFree101a pump control (condenser)FreeControl of the simultaneous Yv203, Yv204 valveopening source evaporator sideControl of the simultaneous Yv203, Yv204 valveclosing source evaporator sideFree23

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!