4. Fouled Extractor5. Extractor Defective or Missing6. Damaged EjectorClean Extractor.Replace.Replace if necessary.54E. SPENT CASE OR ROUND STUCK IN CHAMBERCaution: The following procedure should be carried out only after following thesteps in “Immediate Action” (see page 49).1. Remove bolt and striker assembly.2. With barrel in place, insert cleaning rod through front of barrel. Push or tapgently to remove obstruction.3. Check chamber and bore. Clean before reassembly.4. If obstruction cannot be removed, disassemble barrel and contact a certified DTAArmorer.