<strong>HLF</strong> WALK RAMP KITINSTALLATION INSTRUCTIONSAdjustment of Parting BarThe Parting Bar must be located in the fully retractedposition as show to right.Fully retracted Parting BarTighten nuts and bolts to <strong>50</strong> ft lbs.GR02799Final InspectionAfter all components from Walk Ramp Kit have beeninstalled, carefully run liftgate through a complete cycleto check for interferences.Check platform storage:- Ensure Up-Stops contact Platform Brackets- Ensure liftgate does not extend beyond steel ofDock BumperCheck platform operation:- Ensure platform does not contact Walk RampBracket nor Up-Stops when opening and closing.- If contact does occur, the Parting Bar was notadjusted or the bed height is too low.Check Up-Stopcontact &liftgate locationCheck forcontact whileopening andclosing liftgateGR0280880101571 E.O. 6708 Rev. 06Page 49