Installation (For Qualified Installers Only) 11Venting the <strong>Pellet</strong> <strong>Stove</strong>• INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.• DO NOT CONNECT THE PELLET VENT TO A VENT SERVING ANY OTHER APPLIANCE ORSTOVE.• DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.• USE AN APPROVED WALL THIMBLE WHEN PASSING THE VENT THROUGH WALLS ANDA CEILING SUPPORT/FIRE STOP SPACER WHEN PASSING THE VENT THROUGHCEILINGS (MAKE SURE TO MAINTAIN CLEARANCE TO ANY COMBUSTIBLES).• No more than one tee and 180° of elbows (one tee with two 90° elbows, one tee with one 90° andtwo 45° elbows, etc.).Maximum Venting Distance40 Feet(max.)• Vent must have a support bracketevery 5' (1.524 M) of pellet ventwhen on exterior of structure.35 FeetNOTE: Travis Industriesrecommends a minimum verticalvent of 5’ to ensure adequate draftduring a power outage.T he vent height and runmust not exceed thedis tance s hown in theshaded region shown to theright.30 Feet25 Feet20 FeetV enting into this s hadedarea may require restrictoradjustments. See thes ection “R es trictorAdjus tment” for details .15 FeetNOT E : T o achieve optimumperformance, werecommend keeping thevent as short as possible(horizontal run especially).10 Feet5 Feet0 Feet0 Feet5 Feet10 Feet(max.)© Travis Industries 4130924 100-01330_004