Maintenance 39Yearly Maintenance (or Every Ton of <strong>Pellet</strong>s) - Clean the Convection Blower1. Remove the knob on the left side of the stove holding the side door in place, then remove the door.2. Remove the top and bottom screws securing the convection blower cover and remove the coveras shown below (5/16” nutdriver).3. Remove the 2 nuts securing the blower using a 7/16” nutdriver. Lift out and remove theconvection blower from the stove as shown below.4. Remove all dust and debris from the convection blower.NOTE: Take care to prevent damaging the combustion blower impellers.© Travis Industries 4130924 100-01330_004