12.07.2015 Views

AGP Pellet Stove - Avalon

AGP Pellet Stove - Avalon

AGP Pellet Stove - Avalon

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Installation (For Qualified Installers Only) 15Installation ExamplesInstallation Example: Direct "Through-the-wall" InstallationHorizontal Rain Cap12” MinimumType "L" VentHouse Shield (used to protectexterior wall from sootdiscoloration) is HIGHLYRECOMMENDEDWall Thimble(note clearancebetween vent andcombustibles)3” Minimum6” Minimum6” MinimumFloor Protection500° F. RTVSiliconeSeal each ventsection (includingadapters, elbows,etc...) by injecting aliberal amount of500° F. RTVsilicone into the gapbetween sections,unless otherwisespecified by themanufacturer.3” Minimum12”MinimumFloor ProtectionNOTE: Travis Industries recommends a minimum vertical vent of 5’ to ensure adequate draft during apower outage.Install the vent at the clearance specified by the vent manufacturer.© Travis Industries 4130924 100-01330_004

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!