12.07.2015 Views

1535 Relative Humidity Transmitter - Novatech Controls

1535 Relative Humidity Transmitter - Novatech Controls

1535 Relative Humidity Transmitter - Novatech Controls

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

!4. DRIER HEATING Options:TYPE1. Indirect (heat exchanger)2. Direct Fired CombustionIf (1) is selected, the next set-up step is 7.If (2) is selected go to step 5.Figure 4.3 Set-Up Mode Selection Steps 4 to 75. PROBE REFERENCE This set-up function will appear only if 'direct fired' is selected in set-up #4. IfGAS'indirectly' is selected, this step will not appear on the set-up menu.Choose 'Ambient Air' if the drier has a fixed combustion system (fixed firing rate) where thereduction of oxygen due to combustion is constant. A refrigerated or ambient drier system willnot be necessary to condition reference gas from within the drier. The accuracy of thetransmitter is further improved if the combustion gas is a small percentage of the recirculatingdrier air.If the reduction of oxygen due to the combustion is not constant, then choose 'Process Gas'. Arefrigerated or ambient cooler will now be required. See <strong>Novatech</strong> <strong>Controls</strong> or their agent fordetails of availability.Options:1. Ambient air2. Dried process gas from within the drierIf (1) is selected the next set-up step is 6. If (2) is selected the next set-up step is 8.NOVATECH HUMIDITY TRANSMITTER Page 39