PART 2HARDWARE2.1a Mounting on a DIN RailFigure 2.1 MountingTo install unit onto DIN Rail:a) Tilt unit, positionmounting slot onto DINRail, as shown.b) Push unit towards DINRail and it will snap intoplace.2.1b Removal from a DIN RailFigure 2.2 Removal1. Insert flat screw-driverinto tab and pushdownwards.2. Unit will detach from DINRail.2.2 DIP SwitchesThe <strong>iServer</strong> is shippedwith all DIP switchesin "OFF" position1 To change the IP address fromthe serial port2 To change to default factorysettings3 To enable/disable DHCP4 To enable/disable TerminalServer functionONFigure 2.2 DIP Switches4OFF4321ONOFF4321