TT5001 Solvent-Sensing Cable0.27 in.(6.9 mm)Fluoropolymer braidContinuity wire (red)Spacer wire (white)Signal wire (yellow)0.52 in.(13 mm)Conductive polymer jacketSensing wires (black)Drawing not to scale<strong>Product</strong>characteristics Cable diameter 0.27 in. (6.9 mm) nominalCable connector diameter0.52 in. (13 mm) nominalCable weight (50-ft length)2.4 lbOperating temperature range–20°C to 60°C (–4°F to 140°F)Pull <strong>for</strong>ce limitNot to exceed 50 lb (23 kg)Bend radius2 in. (50 mm) minimumPressureLoads greater than 20 lb (9 kg) per linear inch at 20°C (68°F) mayimmediately trigger an alarm.NonresettableMust be replaced after exposure to solvents.Chemicalresistance Cable functions normally after Sulfuric acid (10%)exposure in accordance with Nitric acid (10%)ASTM D 543 at 23°C (73°F) Hydrochloric acid (10%)<strong>for</strong> seven days: Sodium hydroxide (10%)<strong>Water</strong>resistance Sensing cable Less than 10-µA leakage when immersed in salt water <strong>for</strong> 90 days.Connector systemLess than 10-µA leakage when immersed in water at 10 psig <strong>for</strong> 24 hours.Responsetime Representative materials detected: Typical response time at 20°C (68°F):Toluene10 min.Dichloromethane (methylene chloride) 5 min.1, 1, 1-trichloroethylene (TCE) 8 min.Trichloroethane (TCA)20 min.Methyl ethyl ketone (MEK) † 10 min. †Acetone † 10 min. †n-methyl pyrrolidone (NMP) † 60 min. †Isopropyl alcohol (anhydrous)90 min.Notes:• Response times are based on 2 inches of cable immersed in liquid.• Response times are affected by operating temperature. Consult factory <strong>for</strong> specific response times at other temperatures andin other liquids.† Prolonged immersion in ketones will inhibit sensing-cable per<strong>for</strong>mance.ApprovalspendingISO 9001Underwriters LaboratoriesC-UL (certified to Canadian standards)Factory MutualThe <strong>TraceTek</strong> products group is a part of Raychem Chemelex Division. Chemelex Division is ISO 9001 certified.Raychem CorporationCommercial & Industrial Infrastructure Division300 Constitution DriveMenlo Park, CA 94025-1164Tel (800) 545-6258Fax (800) 611-2323Fax-on-Demand (800) 329-4494ciinfo@raychem.comwww.raychem.comAll in<strong>for</strong>mation, including illustrations, is believed to be reliable. Users, however, should independentlyevaluate the suitability of each product <strong>for</strong> their application. Raychem makes no warranties as to theaccuracy or completeness of the in<strong>for</strong>mation, and disclaims any liability regarding its use. Raychem’sonly obligations are those in the Raychem Standard Terms and Conditions of Sale <strong>for</strong> this product,and in no case will Raychem be liable <strong>for</strong> any incidental, indirect, or consequential damages arisingfrom the sale, resale, use, or misuse of the product. Specifications are subject to change withoutnotice. In addition, Raychem reserves the right to make changes—without notification to Buyer—tomaterials or processing that do not affect compliance with any applicable specification.© 1995 Raychem Corporation Printed in USA H55473 5/96 <strong>TraceTek</strong> is a trademark of Raychem Corporation.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!