13.07.2015 Views

R TraceTek Leak Detection Product Selection Guide for Water

R TraceTek Leak Detection Product Selection Guide for Water

R TraceTek Leak Detection Product Selection Guide for Water

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

R <strong>TraceTek</strong> ®Operating Principles <strong>for</strong> <strong>Leak</strong><strong>Detection</strong> and Locating Systems<strong>TraceTek</strong> Sensing Circuit<strong>Leak</strong> <strong>Detection</strong>The sensing cable has two insulatedwires and two conductive polymer coatedelectrodes.A small DC voltage (5-9 volts) is appliedto the sensing cable, and internalresistors limit the current flow through thesensor cable loops to approximately 75microamps. The actual amount of currentflowing is monitored by measuring thevoltage drop (V 1 ) across an internalreference resistor.If a spill occurs, additional current willseek the path of least resistance and flowacross the leak. This results in increasedcurrent flow through the referenceresistor. The resultant increased voltagedrop across the reference resistor signalsthe module to turn on the alarm.Continuity MonitoringIf the cable is broken, no current will flowin the loop. The voltage across thereference resistor decreases to zero andthe internal circuitry recognizes this as acontinuity fault.+V 10.2ContinuityNormal0.8<strong>Leak</strong> detection is accomplished by monitoring thevoltage across an internal reference resistor.<strong>Leak</strong><strong>Leak</strong><strong>Leak</strong>V 1 meter reading<strong>Leak</strong> Location+After a leak has been detected, thecircuitry in the module is automaticallyreconfigured into the locating mode.The digital readout of the location isgenerated by measuring the voltage dropalong the sensing cable between the leakand the module. The voltage drop islinear and proportional to the leaklocation. A different scaling factor isapplied <strong>for</strong> feet, meters, or zones.Raychem CorporationCommercial & Industrial Infrastructure Division300 Constitution DriveMenlo Park, CA 94025-1164Tel (800) 545-6258Fax (800) 611-2323www.raychem.comV2<strong>Leak</strong> location is determined by measuring voltagedrop along the cable from the module to the leak.Distance read-out isproportional to V2© Raychem Corporation Printed in USA 8/93 H54534

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!