13.07.2015 Views

R TraceTek Leak Detection Product Selection Guide for Water

R TraceTek Leak Detection Product Selection Guide for Water

R TraceTek Leak Detection Product Selection Guide for Water

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

RTTC<strong>TraceTek</strong> Sensing Module with Relay ContactsThe <strong>TraceTek</strong> TTC module offers a lowcost option <strong>for</strong> liquid leak detection. It isdesigned <strong>for</strong> use with any <strong>TraceTek</strong> sensingcable, and can be integrated into avariety of monitoring systems. The TTCmodule includes three sets of relay contactswhich can be used <strong>for</strong> remoteannunciation and equipment control. Aremote annunciation device is available.Easy setupAll field wiring connections are easilymade to a terminal strip molded into thebase of the module. The module can beinstalled to reset automatically when thesensing cable dries following a leak, orto require a manual reset using the buttonprovided. The TTC module includesadjustments <strong>for</strong> sensitivity to leaks, and<strong>for</strong> the time delay be<strong>for</strong>e the leak alarmrelay trips. These adjustments can bemade in the field.Versatile designThe TTC module provides separaterelays <strong>for</strong> leak alarms and troublealarms. The <strong>Leak</strong> relay has two sets ofcontacts so it can be used both toannunciate the alarm, and to providedirect control linkage to local devices.However, the system is not designed <strong>for</strong>constant switching applications. TheCable Break alarm monitors the integrityof sensing cable and jumper cable, andwill trip if continuity is lost. This troublerelay is normally energized, so it will alsosignal if there is a loss of power.The TTC module may be installed innon-hazardous indoor locations. Its smallsize allows <strong>for</strong> mounting in or on walls,or on DIN 1 rail systems.ApplicationsThe TTC is ideally suited to be simplyintegrated into centralized monitoringsystems <strong>for</strong> large facilities. Typical applicationsinclude monitoring <strong>for</strong> leaks fromindividual pieces of equipment such asair-handling units, water-cooled machinery,single tanks, pumps, sumps, orother locations where a single length of<strong>TraceTek</strong> sensing cable is used.2 in.(52 mm)4.2 in.(106 mm)Raychem<strong>TraceTek</strong>LEAKCABLE BREAKIDENT:4.4 in.(112 mm)RESETLEAK DETECTORRELAYPOWERTTCTechnical In<strong>for</strong>mation Sensing cable compatibility All <strong>TraceTek</strong> sensing cablesMax length of sensing cable (per channel) 100 ft (30 m)Temperature rating32°F to 122°F (0°C to 50°C)Plastic enclosure NEMA 1, IP 20Weight0.77 lbs (0.35 kg)Power supply requirement 12 to 24 Vac; 50/60 Hz 250 mA(trans<strong>for</strong>mer not included) 15 to 24 Vdc 150 mATerminal block wiring 14 AWG (max. 2.5 mm 2 )<strong>TraceTek</strong> jumper cable wiring 18 AWG (4 x 1 mm 2 )Relays <strong>Leak</strong> 1 DPDT, Form C5 A rating at 30 Vdc or 250 VacTrouble 1 SPDT, Form C5 A rating at 30 Vdc or 120 VacNormally energizedOrdering In<strong>for</strong>mation Catalog Number DescriptionTTC-1TTC alarm module with relay contactsAccessories: TTE-XAL External audible alarmTTC-DRCDIN 1 rail mounting clip

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!