13.07.2015 Views

R TraceTek Leak Detection Product Selection Guide for Water

R TraceTek Leak Detection Product Selection Guide for Water

R TraceTek Leak Detection Product Selection Guide for Water

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

TTC <strong>TraceTek</strong> Sensing Module with Relay ContactsModule Functions1 MINEALEAK indicator (red LED)Indicates system has detected a liquid leak.Raychem <strong>TraceTek</strong> ® 19LEAKA1817 COM16 NCCABLE BREAKNOB1514 C2IDENT:13 NC212 NO211 NO110 NC19 C187RESET C6<strong>Leak</strong> <strong>Detection</strong>5 GRNRelay4 RED3 BLKPOWERD2 YEL1TTCLATCHENABLE0 2 MININCREASETIME DELAYTROUBLERELAYLEAKDETECTIONRELAYPOWERINPUT12-24 VAC15-24 VDCSENSINGCABLELOW HIGHINCREASESENSI-TIVITYFBCDEFCABLE BREAK indicator (yellow LED)Indicates system has detected a break in the sensing cable.RESET switch and indicator (red LED)Indicates leak relay has been activated. Push to reset manually.POWER monitor (green LED)Indicates the system is on.Adjusts time delay (0-2 minutes).Adjusts sensitivity.Terminal Block Wiring191817 COM16 NC15 NO14 C213 NC212 NO211 NO110 NC19 C18765 GRN4 RED3 BLK2 YEL1Typical configurationApproval In<strong>for</strong>mationRLISTEDISO 9001LATCHOVERRIDETROUBLERELAYLEAKDETECTIONRELAYPOWERINPUT12-24 VAC15-24 VDCSENSINGCABLE®Raychem CorporationCommercial & IndustrialInfrastructure Division300 Constitution DriveMenlo Park, CA 94025-1164Tel (800) 545-6258Fax (800) 611-2323www.raychem.com1918171615141312111098765432118 – 19 Latch enable (Jumper enables alarm relay to latch.)*15 – 17 Trouble relay (SPDT)9 – 14 <strong>Leak</strong> alarm relay (DPDT)7 – 8 Power input, 12-24 volts AC or 15-24 volts DC6 Open (Do not use.)2 – 5 Sensing cable (2-yellow, 3-black, 4-red, 5-green)1 Open (Do not use.)The TTC module is UL Listed and CSA Certified <strong>for</strong> use in ordinary areas.The <strong>TraceTek</strong> products group is a part of Raychem Chemelex Division.Chemelex Division is ISO 9001 certified.*Note: If jumper is removed, leak relay automatically resets whensensing cable driesAll in<strong>for</strong>mation, including illustrations, is believed to be reliable. Users, however, should independently evaluate thesuitability of each product <strong>for</strong> their application. Raychem makes no warranties as to the accuracy or completeness ofthe in<strong>for</strong>mation, and disclaims any liability regarding its use. Raychem’s only obligations are those in the RaychemStandard Terms and Conditions of Sale <strong>for</strong> this product, and in no case will Raychem be liable <strong>for</strong> any incidental,indirect, or consequential damages arising from the sale, resale, use, or misuse of the product. Specifications aresubject to change without notice. In addition, Raychem reserves the right to make changes—without notification toBuyer—to materials or processing that do not affect compliance with any applicable specification.© 1990, 1996 Raychem Corporation Printed in USA H53587 10/96 <strong>TraceTek</strong> is a trademark of Raychem Corporation.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!