13.07.2015 Views

R TraceTek Leak Detection Product Selection Guide for Water

R TraceTek Leak Detection Product Selection Guide for Water

R TraceTek Leak Detection Product Selection Guide for Water

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>TraceTek</strong>TTDMCH01 SIMSIM Normal13-May-2002 15:3013 14 15 16 17 20 21 22 23 24RS–RS+ACACTTSIM-1<strong>Leak</strong> Location ModuleRATING: 24Vac ±10%50/60 Hz 3VANetworkAddressRS–RS+ACACREDGRNYELBLKGND8 9 10 11 12<strong>TraceTek</strong>TTDMCH01 SIMSIM Normal13-May-2002 15:3013 14 15 16 17 20 21 22 23 24RS–RS+ACACTTSIM-1<strong>Leak</strong> Location ModuleRATING: 24Vac ±10%50/60 Hz 3VANetworkAddressRS–RS+ACACTTDM-128<strong>TraceTek</strong> <strong>Leak</strong> <strong>Detection</strong>Master ModuleEasy setup and simple operationThe TTDM-128 module directly monitors up to 1500 m (5000 ft) ofsensor cable and a network of up to 128 remote <strong>TraceTek</strong> modules.The remote modules may be a combination of sensor interfacemodules (TTSIM), relay modules (TT-NRM) or additional TTDM-128modules. With its networking capability, the TTDM-128 providestremendous fl exibility in terms of system layout options and monitoringcapability.When liquid is detected on any of the sensors, the TTDM-128sounds an alarm, closes relay contacts, turns on a front panel LEDand displays the circuit identifi cation and location of the leak on thealphanumeric display. The leak detection event is logged to a nonvolatileevent history fi le. All status and event in<strong>for</strong>mation is madeavailable via the front panel keyboard or RS232/RS485 modbusdigital communication to a host computer, PLC or plant/buildingautomation system.Each sensor circuit detects, locates and tracks leaks independentlyfrom any other circuits connected to the TTDM-128. There is noloss of sensitivity and no re-mapping required after an initial leak isdetected. A simple map showing where the sensors are installed isthe only fi eld calibration requirement.Design Features• Multiple event tracking capability <strong>for</strong> up to 128 independent sensorcircuits.• Summary relay contacts, LED status lights, LCD in<strong>for</strong>mation displayat the TTDM-128 panel.• Standard external interface modes include: dry contacts, andRS232/RS485 modbus communication. A 4-20 mA analog outputoption is available.• Event history accessible from the front panel or via serial port toidentify type of event, time, location, and other parameters <strong>for</strong> allsensor events or user adjustments and interventions.• Layered password protection <strong>for</strong> setup changes.• Adjustable sensitivity and selectable measurement units.• Universal power supply <strong>for</strong> 120/240 Vac 50/60 Hz (24 volt optionavailable).• Non-volatile memory <strong>for</strong> event history, setup and networkconfi guration.• Complete remote operation and monitoring through modbuscommunications or using optional TT-SUPERVISOR Windowssoftware.20 mm(0.79 in)300 mm(11.81 in)261 mm(10.28 in)20 mm(0.79 in)85 mm(3.35 in)25 mm(1 in)CH01 SIMSIM Normal<strong>TraceTek</strong>TTDM200 mm(7.87 in)240 mm(9.45 in)7mm(5/16in)mountinghole(4places)SHLDSHLDREDGRNYELBLKGND8 9 10 11 12<strong>TraceTek</strong> Network ArrangementTTDM-128Master ModuleTTSIMSensor InterfaceTTDM-128TTSIMTo additional TTDMs,TTSIMs or TT-NRMsSHLDSHLDRS-232 or RS-485modbus link tohost systemRS-485 2 wire network<strong>Detection</strong> cable /sensorsGeneral Features Sensor compatibility All <strong>TraceTek</strong> sensor cables and point sensors orcontact closure devicesMaximum size of networkNumber of TTSIM modules128 (less number of TT-NRMs installed)Maximum number of TT-NRM 10Precision± 0.1% of circuit lengthUnitsFeet, meters or zonesDisplay languageEnglish, French, German, Spanish, Japanese,ItalianOrdering In<strong>for</strong>mation Catalog Number DescriptionSupply voltage TTDM-128 115 V + 15%, - 20% ; 230 V ± 10% ; 50/60 HzTTDM-128-24V 24 V AC + 5%, - 35% ; 24 V DC ± 20%Accessories TT-NRM Network relay moduleTTSIM-1Network sensor interface moduleTTSIM-1ANetwork sensor interface module with relayTTDM-4/204-20 mA analog output boardTT-SUPERVISORWindows based PC software

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!