13.07.2015 Views

R TraceTek Leak Detection Product Selection Guide for Water

R TraceTek Leak Detection Product Selection Guide for Water

R TraceTek Leak Detection Product Selection Guide for Water

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>TraceTek</strong>TTDMCH01 SIMSIM Normal13-May-2002 15:30<strong>TraceTek</strong>TTDMCH01 SIMSIM Normal13-May-2002 15:30TTDM-128 <strong>Leak</strong> <strong>Detection</strong> Master Module4 line x 20 characterbacklit LCD displayFour LEDs (monitoring,service, leak, fault)UserInterface Ribbonboard cableOptional4-20 mAboardSensorInterfaceboardMotherboardPowersupplyboard<strong>TraceTek</strong>TTDMCH01 SIMSIM NormalPRI: 220SEC:17Membrane keypad Painted steel NEMA 12enclosureTestportRS-485<strong>for</strong> SIMnetworkRS-232/485host portServicerequiredrelay<strong>Leak</strong> relayFault relayPowerEnvironmental Storage Temperature -18°C to 60°C (0°F to 140°F)Operating temperature0°C to 50°C (32°F to 122°F)Humidity5% to 95% non-condensingAudible AlarmPiezo electricPower consumption TTDM-128 Less than 6 VA (5 W)TTDM-128-24V Less than 12 VA (10 W)Interfaces Relays Number: 3 (service required, leak, fault)Type: DPDTRatings: 5 A at 250 V AC / 24 V DC<strong>TraceTek</strong> Network PortRS-485 (2 wire)External Serial Port (to host)RS232 (3 or 5 wire) orRS485 (2 wire)Approvals and certifications The TTDM-128 unit is approved <strong>for</strong> use in ordinary areas. The module must belocated in an ordinary area, but may monitor intrinsically safe <strong>TraceTek</strong> sensorslocated in hazardous locations, as shown below.LISTED76LJSIGNAL SYSTEM UNITTYPE NMTTDM-128OrdinaryareaClass I, Division 2Hazardous Location<strong>TraceTek</strong> sensors in Class I, Division 2,Groups A, B, C, D Hazardous Locations(Zone 2 in Europe).Leader orjumper cableSensor cablePRODUCT SERVICEgeprüfteSicherheitElectromagnetic compatibilityTyco Thermal Controls300 Constitution DriveMenlo Park, CA 94025-1164USATel: (800) 545-6258Fax: (650) 474-7517E-mail: info@tycothermal.comwww.tycothermal.comTTDM-128EUR • USA • JPNLeader orjumper cableOrdinaryAreaZenerBarrierClass I, Division 1Hazardous LocationSensor cableIf protected by an agency approved zenerbarrier, <strong>TraceTek</strong> sensors in Class I,Division 1, Groups A, B, C, D HazardousLocations (Zones 0 and 1 in Europe).Contact Tyco Thermal Controls to selectproper zener barrier.The TTDM-128 enclosure is NEMA 12(IP 54).Important: All in<strong>for</strong>mation, including illustrations, is believed to be reliable. Users, however, shouldindependently evaluate the suitability of each product <strong>for</strong> their particular application. Tyco Thermal Controlsmakes no warranty as to the accuracy or completeness of the in<strong>for</strong>mation, and disclaims any liability regardingits use. Tyco Thermal Controls’ only obligations are those in the Tyco Thermal Controls Standard Terms andConditions of Sale <strong>for</strong> this product, and in no case will Tyco Thermal Controls or its distributors be liable <strong>for</strong>any incidental, indirect, or consequential damages arising from the sale, resale, use or misuse of the product.Specifi cations are subject to change without notice. In addition, Tyco Thermal Controls reserves the right tomake changes – without notifi cation to Buyer – to processing or materials that do not affect compliance withany applicable specifi cation.<strong>TraceTek</strong> and Tyco are trademarks of Tyco Thermal Controls LLC or its affi liates.©2003 Tyco Thermal Controls LLC H56859 1/03

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!