<strong>TraceTek</strong>TTDMCH01 SIMSIM Normal13-May-2002 15:30<strong>TraceTek</strong>TTDMCH01 SIMSIM Normal13-May-2002 15:30TTDM-128 <strong>Leak</strong> <strong>Detection</strong> Master Module4 line x 20 characterbacklit LCD displayFour LEDs (monitoring,service, leak, fault)UserInterface Ribbonboard cableOptional4-20 mAboardSensorInterfaceboardMotherboardPowersupplyboard<strong>TraceTek</strong>TTDMCH01 SIMSIM NormalPRI: 220SEC:17Membrane keypad Painted steel NEMA 12enclosureTestportRS-485<strong>for</strong> SIMnetworkRS-232/485host portServicerequiredrelay<strong>Leak</strong> relayFault relayPowerEnvironmental Storage Temperature -18°C to 60°C (0°F to 140°F)Operating temperature0°C to 50°C (32°F to 122°F)Humidity5% to 95% non-condensingAudible AlarmPiezo electricPower consumption TTDM-128 Less than 6 VA (5 W)TTDM-128-24V Less than 12 VA (10 W)Interfaces Relays Number: 3 (service required, leak, fault)Type: DPDTRatings: 5 A at 250 V AC / 24 V DC<strong>TraceTek</strong> Network PortRS-485 (2 wire)External Serial Port (to host)RS232 (3 or 5 wire) orRS485 (2 wire)Approvals and certifications The TTDM-128 unit is approved <strong>for</strong> use in ordinary areas. The module must belocated in an ordinary area, but may monitor intrinsically safe <strong>TraceTek</strong> sensorslocated in hazardous locations, as shown below.LISTED76LJSIGNAL SYSTEM UNITTYPE NMTTDM-128OrdinaryareaClass I, Division 2Hazardous Location<strong>TraceTek</strong> sensors in Class I, Division 2,Groups A, B, C, D Hazardous Locations(Zone 2 in Europe).Leader orjumper cableSensor cablePRODUCT SERVICEgeprüfteSicherheitElectromagnetic compatibilityTyco Thermal Controls300 Constitution DriveMenlo Park, CA 94025-1164USATel: (800) 545-6258Fax: (650) 474-7517E-mail: info@tycothermal.comwww.tycothermal.comTTDM-128EUR • USA • JPNLeader orjumper cableOrdinaryAreaZenerBarrierClass I, Division 1Hazardous LocationSensor cableIf protected by an agency approved zenerbarrier, <strong>TraceTek</strong> sensors in Class I,Division 1, Groups A, B, C, D HazardousLocations (Zones 0 and 1 in Europe).Contact Tyco Thermal Controls to selectproper zener barrier.The TTDM-128 enclosure is NEMA 12(IP 54).Important: All in<strong>for</strong>mation, including illustrations, is believed to be reliable. Users, however, shouldindependently evaluate the suitability of each product <strong>for</strong> their particular application. Tyco Thermal Controlsmakes no warranty as to the accuracy or completeness of the in<strong>for</strong>mation, and disclaims any liability regardingits use. Tyco Thermal Controls’ only obligations are those in the Tyco Thermal Controls Standard Terms andConditions of Sale <strong>for</strong> this product, and in no case will Tyco Thermal Controls or its distributors be liable <strong>for</strong>any incidental, indirect, or consequential damages arising from the sale, resale, use or misuse of the product.Specifi cations are subject to change without notice. In addition, Tyco Thermal Controls reserves the right tomake changes – without notifi cation to Buyer – to processing or materials that do not affect compliance withany applicable specifi cation.<strong>TraceTek</strong> and Tyco are trademarks of Tyco Thermal Controls LLC or its affi liates.©2003 Tyco Thermal Controls LLC H56859 1/03
TT-NRM<strong>TraceTek</strong> Network Relay ModuleDescriptionThe <strong>TraceTek</strong> TT-NRM Network RelayModule provides the capability toadd up to 320 individual alarm relaysto a <strong>TraceTek</strong> TTDM-PLUS / TTSIMleak detection network. The TT-NRMcommunicates with the TTDM-PLUSvia the same RS-485 network used <strong>for</strong>TTSIMs. The TT-NRM can be installed ina wide variety of configurations, allowingmany leak detection system layoutpossibilities.ExpandableThe TT-NRM is supplied as a base unit(with power supply, communicationsinterface, DIN rail and end blocks)and separate relay modules. Eachrelay module contains 2 independentlyaddressable relays. Up to 16 relaymodules can be installed on each baseunit, and up to 10 base units can beconnected to a single TTDM-PLUS. Theleak detection network can be expandedat any time with minimal ef<strong>for</strong>t.VersatileThe TT-NRM can be installed in largepanels, or wall mounted in its ownoptional enclosure. TT-NRMs can becentrally located with the TTDM-PLUS, ordistributed throughout the leak detectionnetwork to minimize wiring costs. TheTT-NRM can be used to operate valves,control audible or visual alarms, orinterface with other control systems.1.25 in.(32 mm)1.5 in.(38 mm)2 in.(75 mm)0.5 in.(12 mm)0.5 in.(12 mm)ONTxDRxDCRC24V 0V L L L L L LLL4 in.(100 mm)IO/RNIO/ERAddress x 1NNNNNNNNx 10750-312750-512 750-512 750-512 750-6001.4 in.(35 mm)Power supplyRS-485 networkconnection moduleNetworkprocessorRelaymodulesEndterminationWidth= 5.0 in. + 0.5 in, per relay module (+ 3.5 in. <strong>for</strong> optional power supply)= 127 mm + 12 mm per relay module (+ 90 mm <strong>for</strong> optional power supply)Technical In<strong>for</strong>mation Network compatibility TTDM-PLUS / TTSIM networksRelays Number Up to 32 Form A contacts per TT-NRMVoltage rating 250 Vac, 30 VdcCurrent rating 1 AmpIsolation2.5 kVEnvironmental Ratings Storage Temperature -25 °C to 85 °COperating Temperature 0 °C to 55 °CHumidityIngress Protection5% to 95% non-condensingIP 2XPower requirements Supply voltage 110~240 Volts, AC (50/60 Hz)Power consumptionOrdering in<strong>for</strong>mation Catalog number DescriptionBase unit TT-NRM-BASE Base unit with power supply,communication interface and 1 relay outputmodule (2 relays)Relay modules TT-NRM-2RO Relay output module with 2 relays6 W