• Lamp does not turn ON (LAMP indicator is lit)After keeping MAIN POWER in OFF condition for 3 minutesor more, turn ON the MAIN POWER and press POWERbutton. Then confirm the lamp lights up.OKNGReplace the lamp unit.If the lamp goes out approximately 10 minutes after it lightsup, the cumulative usage time of it exceeds 4 000 hours.Replace the lamp unit.• Lamp does not turn ON. (LAMP indicator is flashing)After keeping MAIN POWER in OFF condition for 3 minutesor more, turn ON the MAIN POWER and press POWERbutton. Then confirm the lamp lights up.NGReplace the lamp unit.NGB Replace the B-P.C.Board.• Lamp does not turn ON. (TEMP indicator is flashing)Check whether the air inlet port and air exhaust portnot been blocked.OKNGDo not cover air intake port or air exhaust port.Install the projector so that cold air or hot air from airconditioners does not come in to direct contact withthe air intake port or air exhaust port.Check whether the air filter unit is not clogged.NGCleaning the air filter unit.OKCheck each temperature sensor connector cableconnection.NGConnect a connector properly.OKCheck each temperature sensor.NGReplace temperature sensor.OKA Replace the A-P.C.Board.INF - 19