13.07.2015 Views

SERVICE MANUAL SERIES 360 EP SERIES 360 ES - Precisa

SERVICE MANUAL SERIES 360 EP SERIES 360 ES - Precisa

SERVICE MANUAL SERIES 360 EP SERIES 360 ES - Precisa

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Series <strong>360</strong> <strong>EP</strong> /<strong>ES</strong>Error messages3. Error messages3.1 Operating error(Error disappears with correct use or application)ERROR-No. ERROR responsibility ERROR repairERROR 1 invalid program load right programERROR 2 value out of range density-program use right weightERROR 3 weight too small use higher weightERROR 4 wrong anti-theft-code use right codeERROR 5 wrong anti-theft-code use right codeERROR 8 zero point outside range call serviceERROR 9 / 0 calibration factor bad repeat calibrationERROR 9 / 1 zero point difference too high repeat calibrationERROR 9 / 2 difference of internal weight too high repeat calibrationERROR 9 / 3 calibration factor bad repeat calibrationERROR 9 / 4waitERROR 15 / 1 Supply to low use right power supplyERROR 15 / 2 Supply to high use right power supplyERROR 29 no Delta-temperature-compensation-referenc repeat calibrationERROR 30 no internal reference weight acknowledge with TARE-keyERROR 31 no external reference weight acknowledge with TARE-keyERROR 41 name already used use an other nameERROR 42 name invalid use an other nameERROR 47 too many values use fewer valuesERROR 48 different first unit from input use the original unitERROR 49 too few values use more valuesERROR 53 values out of range +/- 50% use appropriate weightERROR 60 fallen below minimum transformer area call serviceERROR 61 maximum transformer area exceeded call serviceERROR 80 too few values add sampleERROR 81 too many sample cance sampleERROR 90 no disc free cancel discERROR 91 no disc saved add discERROR 92 no sample add sample3.2 Fatal error(Balance stays still, error repair in service mode)ERROR-No. ERROR responsibility ERROR repairERROR 10 no linearisation values repeat linearisationERROR 11 no calibration factor repeat calibrationERROR 12 keine SCS Einschalt-Drift Werte call serviceERROR 21 no SCS temperature compensation values call serviceERROR 22 no temperature compensation values call serviceERROR 23 no SCS temperatur no-linearity compensation values call service<strong>Precisa</strong> Gravimetrics AG Index - D10

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!