Stove Installation (for qualified installers only) 11Chimney Termination Requirements• Must have an approved cap (to prevent water from entering)• Must not be located where it will become plugged by snow or other material• Must terminate at least 3' above the roof and at least 2' above any portion of the roof within 10'Slanted RoofsFlat RoofsChimney mustextend 3'above the roofChimney mustextend 3'above the roofOutside Air RequirementsChimney must extend 2'above any portion of the roofwithin 10' of the chimney• Required for mobile homes & in certain localities (check with building officials)• Must not be drawn from an enclosed space (garage, unventilated crawl space)• Requires the optional outside air boot (for legs) or pedestal.Chimney must extend 2'above any portion of the roofwithin 10' of the chimneyWhen using outside air, find a location where the chimney andoutside air hole do not interfere with structural members of the home.Pedestal (with insulation)directs air to the stove.A hole must be cutthrough the floorprotection andfloor and therodent screennailed in placehere (see theoptional equipmentinstructions forexact sizes)OutsideAir BootOptional Air Duct (must not belonger than 15' and at least 16square inches in cross section)Air may be drawn from a ventilatedcrawl space or use an air duct.Outside air entrance must be placed soit does not become blocked by snow.Travis Industries 93508133 4020509

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!