30.07.2015 Views

AccuStandard®

AccuStandard®

AccuStandard®

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

EPA Method 500 SeriesMethod 502.2 (Continued) VOCs by PID/ELCDThe following solutions represent an alternate source formulation ofMethod 502/524 components based on similar volatility groups.M-502-K1-SET$ 150 / 6 x 1 mL(M-502B-10X, M-502C-02, M-502C-03,M-502C-04, M-502C-05, M-502C-06)M-502B-10X$ 35 / 1 x 1 mLM-502B-10X-PAKSAVE 20% $ 140 / 5 x 1 mL2.0 mg/mL each in MeOH 6 comps.BromomethaneChloroethaneChloromethaneM-502C-02$ 35 / 1 x 1 mLM-502C-02-PAKSAVE 20% $ 140 / 5 x 1 mL2.0 mg/mL each in MeOH 6 comps.BromodichloromethaneDibromochloromethane1,1,-DichloroethyleneM-502C-03$ 35 / 1 x 1 mLM-502C-03-PAKSAVE 20% $ 140 / 5 x 1 mL2.0 mg/mL each in MeOH 9 comps.BromochloromethaneBromoformCarbon tetrachlorideChloroformDibromomethaneM-502C-04$ 35 / 1 x 1 mLM-502C-04-PAKSAVE 20% $ 140 / 5 x 1 mL2.0 mg/mL each in MeOH 14 comps.1,2-Dibromo-3-chloropropane1,2-Dibromoethane1,2-Dichloroethane1,2-Dichloropropane1,3-Dichloropropane1,1-Dichloropropylenecis-1,3-Dichloropropene *trans-1,3-Dichloropropene **DichlorodifluoromethaneTrichlorofluoromethaneVinyl chloridecis-1,2-Dichloroethylenetrans-1,2-DichloroethyleneMethylene chloride1,1-Dichloroethane2,2-DichloropropaneTetrachloroethylene1,1,1-Trichloroethane* cis (1.06 x conc.)** trans (0.94 x conc.)M-502C-05$ 35 / 1 x 1 mLM-502C-05-PAKSAVE 20% $ 140 / 5 x 1 mL2.0 mg/mL each in MeOH 13 comps.BenzeneBromobenzenen-ButylbenzeneEthylbenzenep-IsopropyltolueneNaphthaleneStyreneHexachlorobutadiene1,1,1,2-Tetrachloroethane1,1,2,2-Tetrachloroethane1,1,2-TrichloroethaneTrichloroethylene1,2,3-TrichloropropaneToluene1,2,3-Trichlorobenzene1,2,4-Trichlorobenzene1,2,4-Trimethylbenzene1,3,5-Trimethylbenzenem-XyleneM-502C-06$ 35 / 1 x 1 mLM-502C-06-PAKSAVE 20% $ 140 / 5 x 1 mL2.0 mg/mL each in MeOH 12 comps.sec-Butylbenzenetert-ButylbenzeneChlorobenzene2-Chlorotoluene4-Chlorotoluene1,2-DichlorobenzeneAlternateSourceAlternateSourceAlternateSourceAlternateSourceAlternateSourceAlternateSource1,3-Dichlorobenzene1,4-DichlorobenzeneIsopropylbenzenen-Propylbenzeneo-Xylenep-XyleneMethod 502.2 Volatile Organic MixturesCustom Unregulated VOC'sM-502C-09$ 60 / 1 x 1 mL2.0 mg/mL each in MeOH 39 comps.BromobenzeneBromochloromethaneBromodichloromethaneBromoformBromomethanen-Butylbenzenesec-Butylbenzenetert-ButylbenzeneChloroethaneChloroformChloromethane2-Chlorotoluene4-ChlorotolueneDibromochloromethaneDibromomethane1,3-DichlorobenzeneDichlorodifluoromethane1,1-Dichloroethane1,2-Dichloropropane1,3-Dichloropropane2,2-DichloropropaneWisconsin DNR VOC MixtureS-989 $ 100 / 1 x 1 mL2.0 mg/mL each in MeOH 52 comps.BenzeneBromobenzeneBromodichloromethenen-Butylbenzenesec-Butylbenzenetert-ButylbenzeneCarbon tetrachlorideChlorobenzeneChlorodibromomethaneChloroethaneChloroformChloromethane2-Chlorotoluene4-Chlorotoluene1,2-Dibromo-3-chloropropane1,2-Dibromoethane1,2-Dichlorobenzene1,3-Dichlorobenzene1,4-DichlorobenzeneDichlorodifluoromethane1,1-Dichloroethane1,2-Dichloroethane1,1-Dichloroethenecis-1,2-Dichloroethenetrans-1,2-Dichloroethene1,2-Dichloropropane1,1-Dichloropropenecis-1,3-Dichloropropene *trans-1,3-Dichloropropene **HexachlorobutadieneIsopropylbenzene (Cumene)p-Isopropyltoluene (p-Cymene)Dichloromethane (Methylene chloride)Naphthalenen-Propylbenzene1,1,1,2-Tetrachloroethane1,1,2,2-Tetrachloroethane1,2,3-Trichlorobenzene1,2,4-Trichlorobenzene1,1,2-TrichloroethaneTrichlorofluoromethane1,2,3-Trichloropropane1,2,4-Trimethylbenzene1,3,5-Trimethylbenzene (Mesitylene)1,3-Dichloropropane2,2-DichloropropaneDiisopropyl etherEthylbenzeneHexachlorobutadianeIsopropylbenzenep-IsopropyltolueneMethylene chlorideMethyl tert-butyl etherNaphthalenen-Propylbenzene1,1,2,2-TetrachloroethaneTetrachloroetheneToluene1,2,3-Trichlorobenzene1,2,4-Trichlorobenzene1,1,1-Trichloroethane1,1,2-TrichloroethaneTrichloroetheneTrichlorofluoromethane1,2,4-Trimethylbenzene1,3,5-TrimethylbenzeneVinyl chlorideo-Xylenem-Xylenep-XyleneTechnical Note* cis (1.06 x conc.)** trans (0.94 x conc.)Each ampule contains at least 120% of the stated volume of a solution,allowing easy transfer. Transfer the required amount using a clean calibrationsyringe. Excess solution can be stored in a tightly capped vial, but this is notrecommended. AccuStandard cannot guarantee the integrity of the solutiononce the ampule has been opened. See the EPA method protocol for storageinstructions.Method 502AlternateSourceAlternate Source = Matches Competitive ProductAccuStandard enhances your laboratory’s analytical results while streamlining your purchasing efforts through theAlternate Source Line (ASL) of Analytical Standards. Use ASL’s for Independent lots to other Standard suppliers’ formulations.We compiled a list of most requested CLP, and EPA 500, 600, 8000 series analytical Standard formulations currently offered in the marketplace.See our complete list of ASL products in QC section of this catalog.Tel. 800-442-5290 / 203-786-5290 • Fax 203-786-5287 • Web AccuStandard.com 159

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!