30.07.2015 Views

AccuStandard®

AccuStandard®

AccuStandard®

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ICPContract Laboratory Program (CLP)Interference Check & Analyte StandardsThe common interferents checked for by CLP requirements and their associated analytes are listed in our primary interferent analyte solutions.Occasionally, additional interferents may cause other analytical problems according to CLP SOW ILM03.0. These additional six elements areavailable with their respective analytes in the alternate interferent/analyte solutions.Primary AnalytesCLP-PAN-01-1$ 110 / 100 mLCLP-PAN-01-5$ 225 / 500 mLAt stated conc. (µg/mL) in 5% HNO 3 12 comps.Ag (Silver) 100Ba (Barium) 50Be (Beryllium) 50Cd (Cadmium) 100Co (Cobalt) 50Cr (Chromium) 50Cu (Copper) 50Mn (Manganese) 50Ni (Nickel) 100Pb (Lead) 100V (Vanadium) 50Zn (Zinc) 100Alternate InterferentsCLP-PIN-02-1$ 98 / 100 mLCLP-PIN-02-5$ 185 / 500 mL1000 µg/mL each in 5% HNO 3 6 comps.Cr (Chromium)Cu (Copper)Mn (Manganese)Interferent / Analyte SetsCLP-IA-1-SETCLP-PIN-01-1CLP-PAN-01-1CLP-IA-5-SETNi (Nickel)Ti (Titanium)V (Vanadium)$ 345 / 4 x 100 mLCLP-PIN-02-1CLP-PAN-02-1$ 680 / 4 x 500 mLAlternate AnalytesCLP-PAN-02-1$ 115 / 100 mLCLP-PAN-02-5$ 225 / 500 mLAt stated conc. (µg/mL) in 5% HNO 3 tr. HF12 comps.Al (Aluminum) 100Sb (Antimony) 100As (Arsenic) 100B (Boron) 100Ca (Calcium) 10Fe (Iron) 10Mg (Magnesium) 10Mo (Molybdenum) 100Se (Selenium) 100Si (Silicon) 10Na (Sodium) 100Tl (Thallium) 100Primary InterferentsCLP-PIN-01-1$ 110 / 100 mLCLP-PIN-01-5$ 215 / 500 mLAt stated conc. (µg/mL) in 5% HNO 3 4 comps.Al (Aluminum) 5000Ca (Calcium) 5000Fe (Iron) 2000Mg (Magnesium) 5000CLP-PIN-01-5CLP-PAN-01-5CLP-PIN-02-5CLP-PAN-02-5Detection Limit StandardsContract Required Detection Limits (CRDL) Standard Solutions. We offer the flexibility of two convenient solutions:CLP Detection Limits Standard #1CLP-CRDL-01-1$ 130 / 100 mLAt stated conc. (µg/mL) in 5% HNO 3 15 comps.Sb (Antimony) 120As (Arsenic) 120Be (Beryllium) 10Cd (Cadmium) 10Cr (Chromium) 20Co (Cobalt) 100Cu (Copper) 50Pb (Lead) 120Mn (Manganese) 30Ni (Nickel) 80Se (Selenium) 120Ag (Silver) 20Tl (Thallium) 120V (Vanadium) 100Zn (Zinc) 40Contract Required DetectionLimits (CRDL) SetCLP-CRDL-1-SET $ 205 / 2 x 100 mLCLP-CRDL-01CLP-CRDL-02Technical NoteThese standards are prepared to meet therequirements of the CLP protocol; Arsenic(As), Lead (Pb), Selenium (Se) and Thallium(Tl) are at a concentration of two times theinstrument detection limit (IDL) while theremaining elements are at two times theCRDL.CLP Detection Limits Standard #2CLP-CRDL-02-1$ 130 / 100 mLAt stated conc. (µg/mL) in 5% HNO 3 15 comps.Sb (Antimony) 120As (Arsenic) 20Be (Beryllium) 10Cd (Cadmium) 10Cr (Chromium) 20Co (Cobalt) 100Cu (Copper) 50Pb (Lead) 6Mn (Manganese) 30Ni (Nickel) 80Se (Selenium) 10Ag (Silver) 20Tl (Thallium) 20V (Vanadium) 100Zn (Zinc) 40Technical NoteThese standards are designed for ICPsequipped with ultrasonic nebulizers and theyoffer the elements of interest at two times theCRDL level.ICP Multi-ElementTel. 800-442-5290 / 203-786-5290 • Fax 203-786-5287 • AccuStandard.com 379

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!