WLCP-36WST-S3
WLCP-36WST-S3 - Douglas Lighting Control
WLCP-36WST-S3 - Douglas Lighting Control
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>WLCP</strong>-<strong>36WST</strong>-<strong>S3</strong><br />
WTP-4408 Controller<br />
Mounting<br />
Mounting/Installation<br />
WTP-4408 Controller<br />
The WTP-4408 Photo/Timer is mounted inside the relay control panel<br />
on 35mm DIN rail.<br />
Best to locate the panel in an area that is accessible for programming<br />
the WTP-4408.<br />
Installation environment: indoors, stationary, non-vibrating, noncorrossive<br />
atmosphere and non-condensing humidity.<br />
Ambient operating temperature: +32 0 F to +140 0 F (0 0 C to +60 0 C).<br />
Optional WPS-5527K Sensor Head<br />
Do not mount the sensor where artificial light shines directly on it.<br />
For best results, mount the sensor pointing to the Northern sky.<br />
The WPS-5527K Sensor is waterproof and able to withstand harsh<br />
climate. However, when possible, mount the sensor either indoors<br />
pointing outward or in a sheltered area. The sensor's measurements<br />
will be less affected by dirt, ice or snow build-up. If mounting<br />
outdoors, try to shelter the sensor from the elements. For example,<br />
mount the sensor on the underside of the junction box (as shown in<br />
INSERT A).<br />
The sensor has a plastic mounting nipple that can be threaded to a<br />
1/2" pipe thread. A mounting nut is also supplied for mounting to a<br />
1/2" knockout.<br />
Junction Box<br />
N<br />
Sensor<br />
Wall<br />
6.5"<br />
(165)<br />
3.25"<br />
(83)<br />
12" wire<br />
(#18 AWG)<br />
9 6 2 " " & 6 E A 2 D J + J H A H<br />
Esc<br />
Power<br />
A B C D<br />
1 2 3<br />
Mo<br />
4 5 6<br />
Th<br />
7 8 9<br />
Su<br />
0<br />
Wh<br />
1<br />
Output 2<br />
Output 3<br />
Output 4<br />
Directions<br />
• Buttons A, B, C & D select options shown at Output 5<br />
the bottom of the display. Follow prompts<br />
which appears on the display to set up the<br />
unit and/or view/edit programs<br />
Output 6<br />
• Use only to control Douglas Relays or Relayt<br />
A Scanners.<br />
Output 7<br />
• For more information rfer to "Applications<br />
B & Directions" booklet or visit<br />
Output 8<br />
www.DouglasLighting Control.com<br />
White<br />
Optional WPS-5527<br />
Photo Sensor<br />
lighting controls Blue<br />
Tu<br />
Fr<br />
We<br />
Sa<br />
WPS-5527K<br />
Sensor Head<br />
WTP-4408<br />
Controller<br />
24VAC<br />
Clr<br />
Power for<br />
Outputs<br />
INSERT A<br />
35mm DIN<br />
Rail Mounting<br />
4.0"<br />
(102)<br />
1.75"<br />
(45)<br />
Components <strong>WLCP</strong>-<strong>36WST</strong>-<strong>S3</strong> 1.1<br />
page 10<br />
lighting controls