Each unit shall have its own individual low-inductance earth connection. The use of a<br />

common busbar for grounding is not recommended <strong>as</strong> this can lead to unwanted<br />

common-mode coupling effects.<br />

The ground should be connected to the cabinets metal frame to provide a return path<br />

for fault currents due to equipment malfunction or external faults such <strong>as</strong> lightning faults.<br />

Interconnecting cables must be well screened.<br />