Thrane & Thrane<br />
<strong>TT</strong>-<strong>3020B</strong><br />
Capsat Transceiver<br />
<strong>Installation</strong> <strong>Manual</strong><br />
Each unit shall have its own individual low-inductance earth connection. The use of a<br />
common busbar for grounding is not recommended <strong>as</strong> this can lead to unwanted<br />
common-mode coupling effects.<br />
The ground should be connected to the cabinets metal frame to provide a return path<br />
for fault currents due to equipment malfunction or external faults such <strong>as</strong> lightning faults.<br />
Interconnecting cables must be well screened.<br />