Thrane & Thrane<br />

<strong>TT</strong>-<strong>3020B</strong><br />

Capsat Transceiver<br />

<strong>Installation</strong> <strong>Manual</strong><br />

The T-BUS connector, a standard BNC-type, is located on the rear panel of the<br />

transceiver and is marked X5. The inner conductor carries the data signals and the<br />

outer is the shield.<br />

2.5.3.1 Changing port X5 to input NMEA 0183 data<br />

If the <strong>TT</strong>-<strong>3020B</strong> will be used with a navigator using the NMEA standard, you must follow<br />

the below instructions to ensure proper operation:<br />

1. Turn off the <strong>TT</strong>-<strong>3020B</strong> .<br />

2. Place the <strong>TT</strong>-<strong>3020B</strong> upside-down, remove all 9 screws so that the bottom cover<br />

can be removed.<br />

3. Locate the switch array in the corner of the <strong>TT</strong>-<strong>3020B</strong> CPU board, and set switch 1<br />

and 3 in the OFF position. This selects NMEA input operation. Ple<strong>as</strong>e refer to<br />

figure 7 on page 21.<br />

2.5.3.2 Changing port X5 to output NMEA 0183 data<br />

If the <strong>TT</strong>-<strong>3020B</strong> will be used with an external device using the NMEA standard, you must<br />

follow the below instructions to ensure proper operation:<br />

1. Turn off the <strong>TT</strong>-<strong>3020B</strong> .<br />

2. Place the <strong>TT</strong>-<strong>3020B</strong> upside-down, remove all 9 screws so that the bottom cover<br />

can be removed.<br />

3. Locate the switch array in the corner of the <strong>TT</strong>-<strong>3020B</strong> CPU board, and set switch 1<br />

in the OFF position and switch 3 in the ON position. This selects NMEA output<br />

operation. Ple<strong>as</strong>e refer to figure 7 on page 21.<br />

2.5.3.3 Changing port X5 to T-Bus communication<br />

If the <strong>TT</strong>-<strong>3020B</strong> will be used with a <strong>TT</strong>-3042B Remote Alarm using the T-Bus standard,<br />

you must follow the below instructions to ensure proper operation:<br />

1. Turn off the <strong>TT</strong>-<strong>3020B</strong>.<br />

2. Place the <strong>TT</strong>-<strong>3020B</strong> upside-down, remove all 9 screws so that the bottom cover<br />

can be removed.<br />

3. Locate the switch array in the corner of the <strong>TT</strong>-<strong>3020B</strong> CPU board, and set switch 1<br />

in the ON position. This selects T-Bus operation. Ple<strong>as</strong>e refer to figure 7 on page<br />

21.<br />