To reset the red ALARM indicator, press the ALARM button only on the Transceiver<br />
frontpanel for 5 seconds.<br />
4.5 Commissioned status<br />
When the commisioning procedure h<strong>as</strong> been completed, the Transceiver will store this<br />
status in it's non-volatile EEPROM memory.<br />
A special feature of the Transceiver is that when it is commissioned it will check its<br />
current login status when powered on.<br />
If it is logged out, it will automatically issue a login to the l<strong>as</strong>t used NCS TDM.<br />
4.6 Uncommissioned status<br />
Though your <strong>TT</strong>-<strong>3020B</strong> Transceiver is not commissioned, it is fully capable of receiving<br />
messages.<br />
You are not denied permission to transmit messages by means of the <strong>TT</strong>-<strong>3020B</strong> Capsat<br />
Transceiver when your equipment is uncommissioned, but the LES will not forward your<br />
messages to their destinations, and a non-delivery notification is returned to you. You<br />
may also see the message "Your Transceiver is not commissioned" on the printer or<br />
screen.<br />
Any distress alerts will not be barred or rejected by the system.<br />
Page 44 30MAY95