OGTS Bypass System Fluid Flow Model Input Data, Piping/Component Descriptions and Flow Loss Coefficients.<br />

J9 Lateral Wye, Forward<br />

Direction<br />

30° Lateral Wye,<br />

Main Flow<br />

OGTS Bypass System Fluid Flow Model<br />

6 x 6 x 6 40S 6.065 6.000 ED5-2 0.290<br />

Component Details Size Schedule Inside Dia. L ASHRAE ASHRAE Cv<br />

Fitting Loss<br />

No Coef.<br />

(in) (in) (in)<br />

P9 Piping, 6-VOG-36-0286 6" straight duct, S.Stl 6 40S 6.065 10.500 CDl l-1 ARROW<br />

J10 Valve, HV-901 6" Keystone, FIG.<br />

362-173, Key-Lok<br />

6 5.8125 2.250 1194<br />

P10 Elbow 90° Elbow, R/D =<br />

1.5, S.Stl<br />

6 40S 6.065 CD3-1 0.050<br />

P 00 Piping, 6-VOG-36-0286 6" straight duct, S.Stl 6 40S 6.065 8.000 CDl l-1 ARROW<br />

J11 Lateral Wye Reverse<br />

Direction<br />

300 Lateral Wye,<br />

Main Flow<br />

6 x 6 x 6 40S 6.065 6.000 ED5-2 0.110<br />

Component Details Size Schedule Inside Dia. L ASHRAE ASHRAE<br />

Fitting Loss<br />

No Coef.<br />

(in) (in) (in)<br />

J9<br />

Pl l<br />

Lateral Wye, Forward<br />

Direction<br />

Piping, 6-VOG-36-0286<br />

30° Lateral Wye,<br />

Branch Flow<br />

6" straight duct, S.<br />

6 x 6 x 6 40S 6.065 6.000 ED5-2 0.610<br />

Sri<br />

6 40S 6.065 6.000 CDl l-1 ARROW<br />

I'll Elbow 300 Elbow, R/D =<br />

6 105 6.065 CD3-1 0.050<br />

1.5, S.Stl<br />

J12 Valve, HV-902 6" Keystone, FIG.<br />

362-173, Key-Lok<br />

6 5.8125 2.250 1194<br />

P12 Piping, 6-VOG-36-0286 6" straight duct, S.Stl 6 40S 6.065 6.000 CDl 1-1 ARROW<br />

Cv<br />

b<br />

N<br />

A<br />

C<br />

a

Hooray! Your file is uploaded and ready to be published.