OAT$ Bypass S ^te^ ^1u1^^„iP^^^^de ^^^<br />

Component Details Size Schedule Inside, Dia. L ASHRAE-<br />

Fitting<br />

No<br />

(in) (in) (in)<br />

ASHRAE<br />

Loss<br />

Coef.<br />

" Piping, 8-VOG-36-0286 8" straight duct, S.Stl 8 lOS 8.329 15.000 CD11-1 ARROW<br />

" Expansion Joint, EJ-635 +<br />

5 others<br />

8" Expansion joint 8 7.900 11.000 CR6-3 0.660<br />

P14 Piping, 8-VOG-36-0286 8" straight duct, S.Stl 8 lOS 8.329 1805.000 CD11-1 ARROW<br />

Total 1969.000 inches 0.770<br />

J14 45° Lateral 45° Lateral Flow<br />

Thru branch closed<br />

• Calculation No. 145579-D-C*6, Rev. 1<br />

Attachment<br />

Page 9 of 22<br />

OGTS Bypass System Fluid Flow Model Input Data, Piping/Component Descriptions and Flow Loss Coefficients.<br />

164.083" ft<br />

8 x 8 x 8 lOS 8.329 ARROW ARROW<br />

P15 Piping, 8-VOG-36-0286 8" straight duct, S. Sit 8 los 8.329 65.500 CD11-1 ARROW<br />

" Elbow #2 90° Elbow, R/D =<br />

1.5, S.Stl<br />

8 los 8.329 CD3-1 0.110<br />

" Piping, 8-VOG-36-0286 8" straight duct, S.Stl 8 los 8.329 100.000 CD11-1 ARROW<br />

" Std Tee Std Tee, Branch flow,<br />

main flow dead<br />

8 x 8 x 8 los 8.329 ARROW 1.10<br />

" Piping, 8-VOG-36-0286 8" straight duct, S.Stl 8 lOS 8.329 101.000 CD11-1 ARROW<br />

P15 Expansion Joint, EJ-615 8" Expansion joint 8 7.900 11.000 CR6-3 0.110<br />

(HEPA Inlet) Total 277.500 inches 1.320<br />

23.125 ft<br />