0 - Hanford Site
0 - Hanford Site
0 - Hanford Site
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
a<br />
Y,<br />
in<br />
A<br />
Calculation No. 145579-DA6, Rev, 1<br />
Attachment 3<br />
Page 8 of 22<br />
OGTS Bypass System Fluid Flow Model Input Data, Piping/Component Descriptions and Flow Loss Coefficients.<br />
;^ 0^^^ A^^^s Y' te ^M1 ^^^^.M^^i^0<br />
h }25<br />
Component Details Size Schedule Inside Dia. L ASHRAE ASHRAE Cv<br />
Fitting Loss<br />
No Coef.<br />
(in) (in) (in)<br />
P12 Elbow 30° Elbow, R/D = 6 40S 6.065 CD3-1 0.130<br />
1.5, S.Stl<br />
,111 Lateral Wye Reverse 30 0 Lateral Wye, 6 x 6 x 6 40S 6.065 6.000 ARROW ARROW<br />
Direction Branch Flow<br />
P13 Piping, 6-VOG-36-0286 6" straight duct, S.Stl 6 40S 6.065 6.000 CDl 1 -1 ARROW<br />
P13 Reducer 6 x 8 Std Reducer, 6 x 8 40S 6.065/8.329 ED4-1 0.170<br />
19°<br />
P13 Elbow #1 90° Elbow, R/D = 8 l OS 8.329 CD3-1 0.110<br />
1.5, S.Stl<br />
P13 Piping, 8-VOG-36-0286 8" straight duct, S.Stl 8 lOS 8.329 114.000 CD1 1 -1 ARROW<br />
P13 EJ-635 8"Expansionjoint 8 los 7.900 11.000 CR6-3 0.110<br />
P13 Piping, 8-VOG-36-0286 8" straight duct, S.Stl 8 lOS 8.329 120.000 CDl l-1 ARROW<br />
x<br />
Total 251.000 inches 0.390<br />
20.917 ft<br />
J13 Lateral Wye, Forward 45 1 Lateral Trough 8 lOS 8.329 10.000 ARROW ARROW<br />
Direction Flow (Air Inlet Bleed<br />
System@ Branch<br />
flow)<br />
P14 Piping, 8-VOG-36-0286 8" straight duct, S.Stl 8 lOS 8.329 138.000 CD1l-1 ARROW<br />
" Elbow #1 900 Elbow, R/D = 8 l OS 8.329 CD3-1 0.110<br />
1.5, S.Stl