<strong>DResearch</strong> – User <strong>Manual</strong> TeleObserver <strong>MR3140</strong>-M 2011-02-03<br />
2.4.8 The audio interface<br />
Use the audio adapter cable which is provided in the accessories to connect external audio devices to<br />
the recorder. The interface (D-SUB 9, female) is wired as follows:<br />
Interface Pin Name Description<br />
5 1<br />
9 6<br />
(female)<br />
Audio interface pin layout<br />
1 Audio PWR2 Microphone phantom voltage 2<br />
2 AudioIn2 Audio input 2<br />
3 GND Audio GND<br />
4 AudioIn1 Audio input 1<br />
5 Audio PWR1 Microphone phantom voltage 1<br />
6 GND Audio GND<br />
7 GND Audio GND<br />
8 GND Audio GND<br />
9 GND Audio GND<br />
2.4.9 GPIO-interface – detector inputs and switch relay outputs<br />
Sensor input 1 ... 6<br />
Relay output 1…4<br />
Recording module<br />
Recording module<br />
Each of the 6 available inputs is constructed as<br />
shown in the adjacent circuit.<br />
Sensor systems can be connected as desired<br />
depending on requirements. This allows the<br />
<strong>MR3140</strong>-M to be fully integrated within existing<br />
systems.<br />
Each of the 4 relay outputs is constructed as<br />
shown (left).<br />
Here too the connection options enable the<br />
recorder to offer full flexibility for the connection of<br />
devices and systems.<br />
It is possible to connect indicators, diodes and<br />
bulbs or to control other whole systems directly.<br />