<strong>DResearch</strong> – User <strong>Manual</strong> TeleObserver <strong>MR3140</strong>-M 2011-02-03<br />

2.4.11 “Ext. Devices“ Interface – IBIS, CAN and RS485<br />

External Devices interface - Pinout<br />

Pin 1 …<br />

14<br />

The (HD-SUB-25, male) socket marked Ext. Devices on the<br />

recorder is an RS485 interface. This is shown as COM4* in the<br />

setup configuration. This connection is used for the connection and<br />

integration of an IBIS system or a rail media coupler. The interface<br />

is also suitable for connecting an external GPS receiver.<br />

A connection for a CAN bus ** is offered as an additional option.<br />

To use this interface the plugset ext. device is required. This can<br />

be obtained from your system integrator or from the manufacturer.<br />

Pin Name Description Pin Name Description<br />

1 GND Ground 14 WBSD IBIS Call -Bus Signal<br />

2 CAN_GND** CAN Ground** 15 WBMS IBIS-GND-Call-Bus<br />

3 CAN_L** CAN_L Bus Signal** 16 WBED IBIS-Response-Bus Signal<br />

4 CAN_H** CAN_H Bus Signal** 17 WBME IBIS-GND- Response -Bus<br />

5 reserved 18 GND Ground<br />

6 GND Ground 19 not used<br />

7 GND Ground 20 reserved<br />

8 reserved 21 not used<br />

9 reserved 22 reserved<br />

10 reserved 23 not used<br />

11 GND Ground 24 GND Ground<br />

12 RS485A RS485 Signal A 25 GND Ground<br />

13 RS485B RS485 Signal B<br />

* IBIS = COM3, RS485 = COM4<br />

** The hardware is prepared to support a CAN-Bus and can be offered.<br />