3 Installation page 15<br />

3.4.2 Initialisation signal<br />

Furthermore lamp operation will not be allowed unless +24V are applied to pin X1.1 and<br />

GND on pin X1.2. This is an additional monitoring function for the safe operation of the<br />

installation. The status of pin X1.1 is visualized in the [Warning Register] of the PROFIBUSinput-data<br />

(see below and paragraph 5.2: Bit 7 {Init Signal Ok}).<br />

If the initialisation signal is deactivated during lamp operation, lamp operation will be shut<br />

down. After re-applying the initialisation signal, the lamp has to be restarted.<br />

3.5 Configuration<br />

Communication between <strong>ELC</strong> and installation control is carried out via PROFIBUS DPV0.<br />

The <strong>ELC</strong> represents a non-modular DPV0-Slave, the installation control functions as the<br />

Master.<br />

For configuration, control and monitoring of the <strong>ELC</strong> 16 input registers (Master receiving data<br />

from <strong>ELC</strong>) were implemented, as well as 6 output registers (Master sending data to <strong>ELC</strong>).<br />

For registers overlapping more than one byte, the byte order was determined according to<br />

”Big-Endian“.<br />

The preset baud rate is recognized automatically by the <strong>ELC</strong>. Software supports all baud<br />

rates from 9.6kBit to12MBit; tested values can be taken from the technical data in chapter 6<br />

(limitations may be caused by the connector).<br />

The necessary adjustments during the installing of the <strong>ELC</strong> will be explained in this<br />

paragraph, the adjustments for lamp operation will follow in chapter 4.<br />

PROFIBUS-input-data (<strong>ELC</strong> → Master)<br />

Byte-<br />

Nr.<br />

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15<br />

Name [<strong>ELC</strong><br />

Serial<br />

Number]<br />

[Software<br />

Version]<br />

[<strong>ELC</strong><br />

Nominal<br />

Power]<br />

<strong>ELC</strong> <strong>PE22</strong>_PE32-V2.2-09.11-GB Subject to technical alterations<br />

[Error<br />

Register]<br />

PROFIBUS-output-data (Master → <strong>ELC</strong>)<br />

Byte-<br />

Nr.<br />

Name [Power<br />

Set<br />

Value]<br />

0 1 2 3 4 5<br />

[Installed<br />

Lamp<br />

Power]<br />

[Lamp<br />

Control]<br />

[Reserved]<br />

[Warning<br />

Register]<br />

[Lamp<br />

Status]<br />

[Actual<br />

Power]<br />

[Actual<br />

Voltage]<br />

[Actual<br />

Current]<br />

[Reserved]