5 Monitoring, warning, error, repair page 27<br />

5.3 Error<br />

5.3.1 Error messages<br />

Effects of an error:<br />

• The lamp will be immediately shut down,<br />

• In case of an error the red Status-LED is blinking (s. Fig. 11),<br />

• Bits in the [Error Register] will be set as soon as the correspondent error occurs.<br />

PROFIBUS-input-data (<strong>ELC</strong> → Master)<br />

Byte-<br />

Nr.<br />

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15<br />

Name [<strong>ELC</strong><br />

Serial<br />

Number]<br />

[Software<br />

Version]<br />

[<strong>ELC</strong><br />

Nominal<br />

Power]<br />

<strong>ELC</strong> <strong>PE22</strong>_PE32-V2.2-09.11-GB Subject to technical alterations<br />

[Error<br />

Register]<br />

[Warning<br />

Register]<br />

Byte 6<br />

↓<br />

[Lamp<br />

Status]<br />

[Actual<br />

Power]<br />

[Actual<br />

Voltage]<br />

Bit 15 14 13 12 11 10 9 8<br />

Name n/a n/a Lamp<br />

Power<br />

Low<br />

Byte 7<br />

internal internal Earth<br />

Leakage<br />

Fault<br />

[Actual<br />

Current]<br />

internal internal<br />

Bit 7 6 5 4 3 2 1 0<br />

Name Lamp<br />

Voltage<br />

High<br />

internal Bus<br />

Connection<br />

Error<br />

internal <strong>ELC</strong><br />

Temperature<br />

High<br />

internal Main<br />

Voltage<br />

Low<br />

internal<br />

Bit 1: An error of the mains is recorded in the {Main Voltage Low}-bit if the mains<br />

voltage falls below the allowed minimum (see chapter 6) during lamp<br />

operation.<br />

Bit 3: The {<strong>ELC</strong> Temperature High} bit is set as soon as the acceptable<br />

temperature is exceeded.<br />

Bit 5: If the PROFIBUS connection is interrupted during lamp operation the {Bus<br />

Connection Error} bit is set. Additionally the green Status-LED (see Fig. 11)<br />

is blinking, or completely off as soon as the internal communication of the <strong>ELC</strong><br />

is interrupted.<br />

Bit 7: If the burning voltage of the lamp is too high the {Lamp Voltage High} bit is<br />

set.<br />