5 Monitoring, warning, error, repair page 27<br />
5.3 Error<br />
5.3.1 Error messages<br />
Effects of an error:<br />
• The lamp will be immediately shut down,<br />
• In case of an error the red Status-LED is blinking (s. Fig. 11),<br />
• Bits in the [Error Register] will be set as soon as the correspondent error occurs.<br />
PROFIBUS-input-data (<strong>ELC</strong> → Master)<br />
Byte-<br />
Nr.<br />
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15<br />
Name [<strong>ELC</strong><br />
Serial<br />
Number]<br />
[Software<br />
Version]<br />
[<strong>ELC</strong><br />
Nominal<br />
Power]<br />
<strong>ELC</strong> <strong>PE22</strong>_PE32-V2.2-09.11-GB Subject to technical alterations<br />
[Error<br />
Register]<br />
[Warning<br />
Register]<br />
Byte 6<br />
↓<br />
[Lamp<br />
Status]<br />
[Actual<br />
Power]<br />
[Actual<br />
Voltage]<br />
Bit 15 14 13 12 11 10 9 8<br />
Name n/a n/a Lamp<br />
Power<br />
Low<br />
Byte 7<br />
internal internal Earth<br />
Leakage<br />
Fault<br />
[Actual<br />
Current]<br />
internal internal<br />
Bit 7 6 5 4 3 2 1 0<br />
Name Lamp<br />
Voltage<br />
High<br />
internal Bus<br />
Connection<br />
Error<br />
internal <strong>ELC</strong><br />
Temperature<br />
High<br />
internal Main<br />
Voltage<br />
Low<br />
internal<br />
Bit 1: An error of the mains is recorded in the {Main Voltage Low}-bit if the mains<br />
voltage falls below the allowed minimum (see chapter 6) during lamp<br />
operation.<br />
Bit 3: The {<strong>ELC</strong> Temperature High} bit is set as soon as the acceptable<br />
temperature is exceeded.<br />
Bit 5: If the PROFIBUS connection is interrupted during lamp operation the {Bus<br />
Connection Error} bit is set. Additionally the green Status-LED (see Fig. 11)<br />
is blinking, or completely off as soon as the internal communication of the <strong>ELC</strong><br />
is interrupted.<br />
Bit 7: If the burning voltage of the lamp is too high the {Lamp Voltage High} bit is<br />
set.<br />
[Reserved]