5 Monitoring, warning, error, repair page 25<br />
Byte 7<br />
Bit 7 6 5 4 3 2 1 0<br />
Name Lamp<br />
Voltage<br />
High<br />
�<br />
internal Bus<br />
Connection<br />
Error<br />
<strong>ELC</strong> <strong>PE22</strong>_PE32-V2.2-09.11-GB Subject to technical alterations<br />
internal <strong>ELC</strong><br />
Temperature<br />
High<br />
internal Main<br />
Voltage<br />
Low<br />
internal<br />
In order to avoid an unwanted reaction of the earth fault control during faultless<br />
operation, the isolation resistance of the lamp cables and all lamp connectors<br />
must be greater than 10 MΩ.<br />
5.2 Warning messages<br />
The bits in the [Warning Register] are divided into two groups:<br />
• Group1-Nibble: the bits 0-3 represent critical operating conditions of the lamp. However<br />
they won’t shut down the lamp.<br />
• Group2-Nibble: If a bit in the Group2-nibble (bits 4-7) is set, the lamp cannot be started<br />
or will be shut down during operation.<br />
The bits of the [Warning Register] will automatically be reset as soon as the triggering status<br />
has been resolved.<br />
PROFIBUS-input-data (<strong>ELC</strong> → Master)<br />
Byte-<br />
Nr.<br />
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15<br />
Name [<strong>ELC</strong><br />
Serial<br />
Number]<br />
[Software<br />
Version]<br />
[<strong>ELC</strong><br />
Nominal<br />
Power]<br />
[Error<br />
Register]<br />
[Warning<br />
Register]<br />
↓<br />
[Lamp<br />
Status]<br />
[Actual<br />
Power]<br />
[Actual<br />
Voltage]<br />
[Actual<br />
Current]<br />
Bit 7 6 5 4 3 2 1 0<br />
Name Init<br />
Signal<br />
Ok<br />
n/a Lamp<br />
Ignition<br />
Failed<br />
Safety<br />
Relay<br />
Open<br />
Group 2:<br />
Lamp operation not<br />
possible<br />
n/a n/a Run<br />
Up<br />
Long<br />
Group 1:<br />
No shut<br />
down<br />
[Reserved]<br />
Lamp<br />
Voltage<br />
Low