5 Monitoring, warning, error, repair page 25<br />

Byte 7<br />

Bit 7 6 5 4 3 2 1 0<br />

Name Lamp<br />

Voltage<br />

High<br />

�<br />

internal Bus<br />

Connection<br />

Error<br />

<strong>ELC</strong> <strong>PE22</strong>_PE32-V2.2-09.11-GB Subject to technical alterations<br />

internal <strong>ELC</strong><br />

Temperature<br />

High<br />

internal Main<br />

Voltage<br />

Low<br />

internal<br />

In order to avoid an unwanted reaction of the earth fault control during faultless<br />

operation, the isolation resistance of the lamp cables and all lamp connectors<br />

must be greater than 10 MΩ.<br />

5.2 Warning messages<br />

The bits in the [Warning Register] are divided into two groups:<br />

• Group1-Nibble: the bits 0-3 represent critical operating conditions of the lamp. However<br />

they won’t shut down the lamp.<br />

• Group2-Nibble: If a bit in the Group2-nibble (bits 4-7) is set, the lamp cannot be started<br />

or will be shut down during operation.<br />

The bits of the [Warning Register] will automatically be reset as soon as the triggering status<br />

has been resolved.<br />

PROFIBUS-input-data (<strong>ELC</strong> → Master)<br />

Byte-<br />

Nr.<br />

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15<br />

Name [<strong>ELC</strong><br />

Serial<br />

Number]<br />

[Software<br />

Version]<br />

[<strong>ELC</strong><br />

Nominal<br />

Power]<br />

[Error<br />

Register]<br />

[Warning<br />

Register]<br />

↓<br />

[Lamp<br />

Status]<br />

[Actual<br />

Power]<br />

[Actual<br />

Voltage]<br />

[Actual<br />

Current]<br />

Bit 7 6 5 4 3 2 1 0<br />

Name Init<br />

Signal<br />

Ok<br />

n/a Lamp<br />

Ignition<br />

Failed<br />

Safety<br />

Relay<br />

Open<br />

Group 2:<br />

Lamp operation not<br />

possible<br />

n/a n/a Run<br />

Up<br />

Long<br />

Group 1:<br />

No shut<br />

down<br />

[Reserved]<br />

Lamp<br />

Voltage<br />

Low