Image Reconstruction for 3D Lung Imaging - Department of Systems ...
Image Reconstruction for 3D Lung Imaging - Department of Systems ...
Image Reconstruction for 3D Lung Imaging - Department of Systems ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
[15] Barber DC, Brown BH, Applied potential tomography, J Phys E: Sci Instrum, 1984,<br />
17, 723-733.<br />
[16] Barber DC, A review <strong>of</strong> reconstruction techniques <strong>for</strong> electrical impedance tomography,<br />
Med Phys, 1989, 16, 162-169.<br />
[17] Barber DC, Brown BH, Single step Algorithms <strong>for</strong> <strong>Image</strong> reconstruction,IEEE Trans.<br />
Biomedical Engineering, 1988, 32, 100-105.<br />
[18] Barber DC, Brown BH, Errors in reconstruction <strong>of</strong> resistivity images using a linear<br />
reconstruction technique, Clin Phys Physiol Meas, 1988, 9, 101-4.<br />
[19] Barrodale I, Roberts FDK, An efficient algorithm <strong>for</strong> discrete l1 linear approximation<br />
with linear constraints, SIAM J Numer Anal, 1978, 15 , 603-611.<br />
[20] Bay<strong>for</strong>d RH, Gibson A, Tizzard A, Tidswell T, Holder DS, Solving the <strong>for</strong>ward problem<br />
in electrical impedance tomography <strong>for</strong> the human head using IDEAS (integrated<br />
design engineering analysis s<strong>of</strong>tware), a finite element modelling tool, Physiol, Meas,<br />
2001, 22, 55-64.<br />
[21] Blott BH, Cox SJ, Daniell GJ, Caton MJ, Nicole DA, High fidelity imaging and high<br />
per<strong>for</strong>mance computing in nonlinear EIT, Physiol Meas, 2000, 21, 7-13,<br />
[22] Blue RS, Isaacson D, Newell JC, Real-time three-dimensional electrical impedance<br />
imaging, Physiol Meas, 2000, 21, 1-12.<br />
[23] Borsic A, Regularisation Methods <strong>for</strong> <strong>Imaging</strong> from Electrical Measurements, PhD<br />
Thesis, Ox<strong>for</strong>d Brooks University, 2002.<br />
[24] Borsic A, Lionheart WRB, McLeod CN, Generation <strong>of</strong> anisotropic regularisation filters<br />
<strong>for</strong> Electrical Impedance Tomography, IEEE Trans Med <strong>Imaging</strong>, 2002, 21, 579- 587.<br />
[25] Borsic A, McLeod CN, Lionheart WRB, Total Variation Regularisation in EIT <strong>Reconstruction</strong>,<br />
Proceedings <strong>of</strong> the 2nd World Congress on Industrial Process Tomography,<br />
2001, 433.<br />
[26] Breckon WR, <strong>Image</strong> reconstruction in electrical impedance tomography. PhD Thesis,<br />
Ox<strong>for</strong>d Polytechnic, 1990.<br />
[27] Brown BH, Seagar AD, The Sheffield data collection system, Clin Phys Physiol Meas,<br />
1987, 8 (suppl A) 91-7.<br />
[28] Brown BH, Leathard AD, Lu L, Wang W, Hampshire A, Measured and expected Cole<br />
parameters from electrical impedance tomographic spectroscopy images <strong>of</strong> the human<br />
thorax, 1995, Physiol Meas, 16, A57-A67.<br />
[29] Calderon AP, On an inverse boundary value problem Seminar on Numerical Analysis<br />
and its Applications to Continuum Physics, Rio de Janeiro: Soc Brasil Mat, 1980,<br />
65-73.<br />
[30] Chan TF, Golub GH, Mulet P, A Nonlinear Primal-Dual Method <strong>for</strong> Total Variation-<br />
Based <strong>Image</strong> Restoration, UCLA Math <strong>Department</strong> CAM Report, 1995, 95-43.<br />
[31] Chan T, Marquina A, Mulet P, High-order total variation-based image restoration,<br />
SIAM Journal on Scientific Computing, 1998, 19, 1046-1062.<br />
128