18.01.2013 Views

Image Reconstruction for 3D Lung Imaging - Department of Systems ...

Image Reconstruction for 3D Lung Imaging - Department of Systems ...

Image Reconstruction for 3D Lung Imaging - Department of Systems ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

[32] Chan T F, Zhou H M, and Chan R H. A continuation method <strong>for</strong> total variation<br />

denoising problems. UCLA CAM Report 95-18, 1995.<br />

[33] Chen ZQ, Paoloni PJ, An integral Equation Approach to Electrical Conductance Tomography,<br />

IEEE Trans on Med <strong>Imaging</strong>, 1992, 11(4), 570-576.<br />

[34] Cheng KS, Isaacson D, Newell JC, Gisser DG, Electrode model <strong>for</strong> electric current<br />

computer tomography, IEEE Transations on Biomedical Engineering, 1989, 36, 918-<br />

924.<br />

[35] Cheney M, Isaacson D, Newell JC, Simske S, Goble JC, NOSER: An algorithm <strong>for</strong><br />

solving the inverse conductivity problem Internat, J <strong>Imaging</strong> <strong>Systems</strong> & Technol 1990,<br />

2, 66-75.<br />

[36] Cohen-Bacrie C, Goussard Y, Guardo R, Regularized reconstruction in electrical<br />

impedance tomography using a variance uni<strong>for</strong>mization constraint, IEEE Trans. Medical<br />

<strong>Imaging</strong>, 1997, 16, 562-571.<br />

[37] Cheney M, Isaacson D, Issues in Electrical Impedance <strong>Imaging</strong>, IEEE Computational<br />

Science and Engineering, 1995, 2, 53-62.<br />

[38] Clay MT, Feree TC, Weighted regularization in electrical impedance tomography with<br />

applications to acute cerebral stroke, IEEE Trans Med <strong>Imaging</strong>, 2002, 21 629-637.<br />

[39] Coleman TF, and Li Y, A globally and quadratically convergent affine scaling method<br />

<strong>for</strong> linear ℓ1 problems, Mathematical Programming, 1992, 56, 189-222.<br />

[40] Cook RD, Salunier GJ, Gisser DG, Goble JC, Newell JC, Isaacson D, ACT3: Highspeed,<br />

high-precision electrical impedance tomograph, IEEE Trans Biomed Imag, 1993,<br />

41, 713-722.<br />

[41] Dehgani H, Soni N, Halter R, Hartov A, Paulsen KD, Excitation patterns in threedimensional<br />

electrical impedance tomography Physiol Meas, 2005 26 S185-S197.<br />

[42] Demidenko E, Hartov A, Soni N, Paulsen K, On Optimal Current Patterns <strong>for</strong> Electrical<br />

Impedance Tomography, IEEE Trans Biomed Eng, 2005, 52, 238-48.<br />

[43] Dickin F, Wang M, Electrical resistance tomography <strong>for</strong> process tomography, Meas Sci<br />

Tech, 1996, 7, 247-260.<br />

[44] Dobson DC, Santosa F, An image enhancement technique <strong>for</strong> electrical impedance<br />

tomography. Inverse Problems, 1994, 10, 317-334.<br />

[45] Dobson D C, Vogel C R. Convergence <strong>of</strong> an iterative method <strong>for</strong> total variation denoising.<br />

SIAM J. on Numerical Analysis, 43, 1779-1791, 1997.<br />

[46] Eyüboglu BM, Brown BH, Barber DC, In vivo imaging <strong>of</strong> cardiac related impedance<br />

changes, IEEE Eng Med Biol Mag, 1989, 8, 3945.<br />

[47] Eyüboglu BM, Pilkington TC, Comments on distinguishability in electrical impedance<br />

tomography, IEEE Trans Biomed Eng, 1993, 40, 1328-1330.<br />

[48] Faes TJC, van Genderingen HR, Noordegraaf AV, Some reflections on the EIT Conference<br />

(London, UK, 22-24 June 2005), Proc. 6th Conf. on Biomedical Applications<br />

<strong>of</strong> EIT. Physiological Measurement, 27, 2005.<br />

129

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!