Fire precautions in dwellings - Norwich City Council
Fire precautions in dwellings - Norwich City Council
Fire precautions in dwellings - Norwich City Council
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
LAYOUT F<br />
Escape from the<br />
rooms <strong>in</strong>to<br />
protected means<br />
of escape<br />
provid<strong>in</strong>g 30<br />
m<strong>in</strong>utes fire and<br />
smoke protection<br />
Index key: Layout F<br />
House type: Bedsit accommodation<br />
Layout: Two or three storey<br />
<strong>Fire</strong> <strong>precautions</strong> <strong>in</strong> dwell<strong>in</strong>gs<br />
• Each bedsit should have own smoke<br />
detector. Ideally ma<strong>in</strong>s powered<br />
but tamper proof detectors with<br />
10year life lithium batteries can be<br />
considered.<br />
2) Doors<br />
• <strong>Fire</strong> doors (FD30S): <strong>in</strong>clud<strong>in</strong>g smoke<br />
seals, <strong>in</strong>tumescent strips and self<br />
closures to all doors open<strong>in</strong>g onto<br />
common area form<strong>in</strong>g the means<br />
of escape.<br />
3) Emergency light<strong>in</strong>g<br />
Emergency light<strong>in</strong>g on each land<strong>in</strong>g<br />
and hallway.<br />
4) Equipment<br />
<strong>Fire</strong> blanket and 2kg dry powder<br />
ext<strong>in</strong>guisher <strong>in</strong> the kitchen.<br />
<strong>Fire</strong> <strong>precautions</strong><br />
1) <strong>Fire</strong> alarm system<br />
a) Whole house<br />
Grade D LD3+ system<br />
Grade D system: A system of<br />
ma<strong>in</strong>s powered <strong>in</strong>terl<strong>in</strong>ked smoke<br />
and heat detectors with <strong>in</strong>tegral<br />
battery back-up.<br />
LD3+ detection. Detection <strong>in</strong> the<br />
follow<strong>in</strong>g areas:<br />
Smoke detectors:<br />
• Hallway and corridor<br />
• Each land<strong>in</strong>g<br />
• Liv<strong>in</strong>g room<br />
Heat detectors:<br />
• In each bedsit with cook<strong>in</strong>g facilities<br />
b) Each bedsit<br />
Grade D LD3 system<br />
Notes:<br />
National fire guidance is provided by Lacors <strong>in</strong> its guide: Hous<strong>in</strong>g – fire safety. This guide can be seen at: www.property<strong>in</strong>fopo<strong>in</strong>t.co.uk. Read the follow<strong>in</strong>g pages <strong>in</strong> guide for further <strong>in</strong>formation.<br />
1. <strong>Fire</strong> alarm system: Pages 23-24 2. <strong>Fire</strong> doors: Pages 21-23 3. Escape w<strong>in</strong>dow: Page 16 4. Emergency light<strong>in</strong>g: Pages 26-27 5. <strong>Fire</strong> fight equipment: Page 28<br />