LAYOUT F<br />

Escape from the<br />

rooms <strong>in</strong>to<br />

protected means<br />

of escape<br />

provid<strong>in</strong>g 30<br />

m<strong>in</strong>utes fire and<br />

smoke protection<br />

Index key: Layout F<br />

House type: Bedsit accommodation<br />

Layout: Two or three storey<br />

<strong>Fire</strong> <strong>precautions</strong> <strong>in</strong> dwell<strong>in</strong>gs<br />

• Each bedsit should have own smoke<br />

detector. Ideally ma<strong>in</strong>s powered<br />

but tamper proof detectors with<br />

10year life lithium batteries can be<br />

considered.<br />

2) Doors<br />

• <strong>Fire</strong> doors (FD30S): <strong>in</strong>clud<strong>in</strong>g smoke<br />

seals, <strong>in</strong>tumescent strips and self<br />

closures to all doors open<strong>in</strong>g onto<br />

common area form<strong>in</strong>g the means<br />

of escape.<br />

3) Emergency light<strong>in</strong>g<br />

Emergency light<strong>in</strong>g on each land<strong>in</strong>g<br />

and hallway.<br />

4) Equipment<br />

<strong>Fire</strong> blanket and 2kg dry powder<br />

ext<strong>in</strong>guisher <strong>in</strong> the kitchen.<br />

<strong>Fire</strong> <strong>precautions</strong><br />

1) <strong>Fire</strong> alarm system<br />

a) Whole house<br />

Grade D LD3+ system<br />

Grade D system: A system of<br />

ma<strong>in</strong>s powered <strong>in</strong>terl<strong>in</strong>ked smoke<br />

and heat detectors with <strong>in</strong>tegral<br />

battery back-up.<br />

LD3+ detection. Detection <strong>in</strong> the<br />

follow<strong>in</strong>g areas:<br />

Smoke detectors:<br />

• Hallway and corridor<br />

• Each land<strong>in</strong>g<br />

• Liv<strong>in</strong>g room<br />

Heat detectors:<br />

• In each bedsit with cook<strong>in</strong>g facilities<br />

b) Each bedsit<br />

Grade D LD3 system<br />

Notes:<br />

National fire guidance is provided by Lacors <strong>in</strong> its guide: Hous<strong>in</strong>g – fire safety. This guide can be seen at: www.property<strong>in</strong>fopo<strong>in</strong>t.co.uk. Read the follow<strong>in</strong>g pages <strong>in</strong> guide for further <strong>in</strong>formation.<br />

1. <strong>Fire</strong> alarm system: Pages 23-24 2. <strong>Fire</strong> doors: Pages 21-23 3. Escape w<strong>in</strong>dow: Page 16 4. Emergency light<strong>in</strong>g: Pages 26-27 5. <strong>Fire</strong> fight equipment: Page 28<br />