<strong>Fire</strong> <strong>precautions</strong> <strong>in</strong> dwell<strong>in</strong>gs<br />
LAYOUT G<br />
Escape from the rooms <strong>in</strong>to protected means of escape<br />
provid<strong>in</strong>g 30 m<strong>in</strong>utes fire and smoke protection<br />
Index key: Layout G<br />
House type: Shared house<br />
Layout: Three floors and shared cook<strong>in</strong>g and bath<strong>in</strong>g facilities<br />
28<br />
LD3+ detection. Detectors <strong>in</strong> the follow<strong>in</strong>g<br />
areas:<br />
Smoke detectors:<br />
• Hallway and corridor<br />
• Each Land<strong>in</strong>g<br />
• Liv<strong>in</strong>g room and d<strong>in</strong><strong>in</strong>g area<br />
Heat detectors:<br />
• In rooms with cook<strong>in</strong>g facilities<br />
2) Doors<br />
Grade D LD2 system<br />
• <strong>Fire</strong> doors (FD30S) <strong>in</strong>clude smoke seals,<br />
<strong>in</strong>tumescent strips and self closures to all<br />
doors open<strong>in</strong>g onto a common area<br />
form<strong>in</strong>g the means of escape.<br />
Grade D LD3 system<br />
• <strong>Fire</strong> doors (FD30): these do not need<br />
smoke seals, but otherwise the same as<br />
FD30S above.<br />
3) Emergency light<strong>in</strong>g<br />
• Emergency light<strong>in</strong>g on each land<strong>in</strong>g and<br />
hallway.<br />
<strong>Fire</strong> <strong>precautions</strong><br />
1) <strong>Fire</strong> alarm system<br />
a) Older converted build<strong>in</strong>gs with poor<br />
fire separation.<br />
Grade D LD2 system<br />
Grade D: System of ma<strong>in</strong>s powered<br />
<strong>in</strong>terl<strong>in</strong>ked smoke and heat detectors with<br />
<strong>in</strong>tegral battery back-up.<br />
LD2 detection: detectors <strong>in</strong> the follow<strong>in</strong>g<br />
areas:<br />
Smoke detectors:<br />
• Hallway and corridor<br />
• Each Land<strong>in</strong>g<br />
• Risk rooms <strong>in</strong>clud<strong>in</strong>g bedrooms, lounge<br />
and d<strong>in</strong><strong>in</strong>g areas<br />
Heat detectors:<br />
• In rooms with cook<strong>in</strong>g facilities.<br />
b) New developments<br />
Grade D LD3+ system<br />
Grade D system of ma<strong>in</strong>s powered<br />
<strong>in</strong>terl<strong>in</strong>ked smoke and heat detectors with<br />
<strong>in</strong>tegral battery back-up.<br />
4) Equipment<br />
<strong>Fire</strong> blanket and 2kg dry powder<br />
ext<strong>in</strong>guisher <strong>in</strong> the kitchen<br />
Notes:<br />
National fire guidance is provided by Lacors <strong>in</strong> its guide: Hous<strong>in</strong>g – fire safety. This guide can be seen at: www.property<strong>in</strong>fopo<strong>in</strong>t.co.uk. Read the follow<strong>in</strong>g pages <strong>in</strong> guide for further <strong>in</strong>formation.<br />
1. <strong>Fire</strong> alarm system: Pages 23-24 2. <strong>Fire</strong> doors: Pages 21-23 3. Escape w<strong>in</strong>dow: Page 16 4. Emergency light<strong>in</strong>g: Pages 26-27 5. <strong>Fire</strong> fight equipment: Page 28