<strong>Fire</strong> <strong>precautions</strong> <strong>in</strong> dwell<strong>in</strong>gs<br />

LAYOUT G<br />

Escape from the rooms <strong>in</strong>to protected means of escape<br />

provid<strong>in</strong>g 30 m<strong>in</strong>utes fire and smoke protection<br />

Index key: Layout G<br />

House type: Shared house<br />

Layout: Three floors and shared cook<strong>in</strong>g and bath<strong>in</strong>g facilities<br />

28<br />

LD3+ detection. Detectors <strong>in</strong> the follow<strong>in</strong>g<br />

areas:<br />

Smoke detectors:<br />

• Hallway and corridor<br />

• Each Land<strong>in</strong>g<br />

• Liv<strong>in</strong>g room and d<strong>in</strong><strong>in</strong>g area<br />

Heat detectors:<br />

• In rooms with cook<strong>in</strong>g facilities<br />

2) Doors<br />

Grade D LD2 system<br />

• <strong>Fire</strong> doors (FD30S) <strong>in</strong>clude smoke seals,<br />

<strong>in</strong>tumescent strips and self closures to all<br />

doors open<strong>in</strong>g onto a common area<br />

form<strong>in</strong>g the means of escape.<br />

Grade D LD3 system<br />

• <strong>Fire</strong> doors (FD30): these do not need<br />

smoke seals, but otherwise the same as<br />

FD30S above.<br />

3) Emergency light<strong>in</strong>g<br />

• Emergency light<strong>in</strong>g on each land<strong>in</strong>g and<br />

hallway.<br />

<strong>Fire</strong> <strong>precautions</strong><br />

1) <strong>Fire</strong> alarm system<br />

a) Older converted build<strong>in</strong>gs with poor<br />

fire separation.<br />

Grade D LD2 system<br />

Grade D: System of ma<strong>in</strong>s powered<br />

<strong>in</strong>terl<strong>in</strong>ked smoke and heat detectors with<br />

<strong>in</strong>tegral battery back-up.<br />

LD2 detection: detectors <strong>in</strong> the follow<strong>in</strong>g<br />

areas:<br />

Smoke detectors:<br />

• Hallway and corridor<br />

• Each Land<strong>in</strong>g<br />

• Risk rooms <strong>in</strong>clud<strong>in</strong>g bedrooms, lounge<br />

and d<strong>in</strong><strong>in</strong>g areas<br />

Heat detectors:<br />

• In rooms with cook<strong>in</strong>g facilities.<br />

b) New developments<br />

Grade D LD3+ system<br />

Grade D system of ma<strong>in</strong>s powered<br />

<strong>in</strong>terl<strong>in</strong>ked smoke and heat detectors with<br />

<strong>in</strong>tegral battery back-up.<br />

4) Equipment<br />

<strong>Fire</strong> blanket and 2kg dry powder<br />

ext<strong>in</strong>guisher <strong>in</strong> the kitchen<br />

Notes:<br />

National fire guidance is provided by Lacors <strong>in</strong> its guide: Hous<strong>in</strong>g – fire safety. This guide can be seen at: www.property<strong>in</strong>fopo<strong>in</strong>t.co.uk. Read the follow<strong>in</strong>g pages <strong>in</strong> guide for further <strong>in</strong>formation.<br />