09.02.2013 Views

Sanitation, heating, air-conditioning (PDF / 6,4 MB - BTI

Sanitation, heating, air-conditioning (PDF / 6,4 MB - BTI

Sanitation, heating, air-conditioning (PDF / 6,4 MB - BTI

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

www.<strong>BTI</strong>-GROUP.COM<br />

07<br />

D<br />

in chapter<br />

Leakage detector 08<br />

B<br />

�����<br />

Electrical soft soldering device<br />

with soldering pliers and flat electrodes, 4 m soldering cable, 2 m connection cable<br />

Item Unit Design weight 230 V<br />

number Pieces kg 50/60 Hz<br />

033938 1 for pipes dia. 6 – 54 mm, 1 /4 – 2 1 /8" 13.6 •<br />

07-927 A/P 07927<br />

Accessories<br />

Item Unit Designation weight<br />

number Pieces Design g<br />

034447 1 Rod electrode with mount (p<strong>air</strong>) 150<br />

034454 1 Flat electrode (p<strong>air</strong>) 30<br />

034461 1 Rod electrode (p<strong>air</strong>) 40<br />

07-927 A/P 07927AA<br />

Universal gas line test device Gw 150/4<br />

Combined test device for leak testing of gas lines and devices with operating pressures up to 100 mbar<br />

g Pre-testing (load test) in acc. with DVGw-TRGI<br />

96 7.1.2 with test pressure of 1.0 bar (maximum<br />

4 bar)<br />

g Testing of main head of water acc. to DVGw.TRGI<br />

96 7.1.3 (leak test) at a test pressure of 110 mbar<br />

g For setting atmospheric burners and blower gas<br />

burners of 0 – 30 mbar<br />

g For testing of liquefied gas (low pressure) at a test<br />

pressure of 40 – 60 mbar in acc. with TRF 96 9.4<br />

g Leak testing of drinking water house installations<br />

acc. to DIN 1988 (TRwI) with compressed <strong>air</strong>,<br />

as combines pre-testing and main testing with<br />

3 bar/110 mbar<br />

g Test equipment mounted in stable steel carrying<br />

case<br />

g Self-testing pressure pump: with non-return valve<br />

and large-sized manometer (dia. 60 mm) 0 – 4 bar,<br />

finely scaled with an accuracy of 0.1 bar divisions<br />

g Gas test plugs, conical or cylindrical, with<br />

pneumatic quick-release<br />

g Meets the requirements of measurement accuracy<br />

acc. to DVGw-TRGI 96 and other German national<br />

safety regulations<br />

Scope of delivery:<br />

g Extension plain coupler for testing liquefied gas,<br />

propane/butane at a test pressure of 150 mbar in<br />

acc. with TRF 96 9.4<br />

g Compressed <strong>air</strong> pump 4 bar<br />

g Pressure container with check valve<br />

g Rubber fan<br />

g Transparent test tube<br />

g Plain coupler, 4 parts with steel box,<br />

360 x 195 x 165 mm (L x w x H)<br />

g with 5 gas test plugs and one-pipe meter hood<br />

Item Unit Designation weight<br />

number Pieces g<br />

002738 1 GW 150/4 with 5 gas test plugs, with one-pipe meter hood 7640<br />

07-916 A/P 07916Ac<br />

544 1006

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!