Fire-protection collar AwM II<br />

For R90 wall and ceiling ducts of flammable pipe lines up to dia. 200 mm; especially for leading through<br />

flammable drainpipe systems<br />

g Smallest housing dimensions<br />

90° bows can be assembled directly after the wall/<br />

ceiling<br />

g Secure structure-borne noise isolation<br />

Insulation up to 4 mm thickness can be led through<br />

the wall/ceiling<br />

g Sloped insertion through the wall is possible<br />

The collar can exceed the outer diameter of the pipe<br />

by up to three times the size<br />

g For core hole drillings, the gap does not need to<br />

be filled for a max. of 5 mm between the pipeline<br />

and the borehole wall<br />

Item Unit Designation<br />

number Pieces<br />

015906 2/10 Fire-protection collar AWM II 50/ 52 mm<br />

014080 2/10 Fire-protection collar AWM II 75/ 77 mm<br />

008327 2/10 Fire-protection collar AWM II 90/ 92 mm<br />

014081 2/10 Fire-protection collar AWM II 110/112 mm<br />

014082 2/10 Fire-protection collar AWM II 125 mm<br />

008326 2/20 Fire-protection collar AWM II 160 mm<br />

008328 2/20 Fire-protection collar AWM II 200 mm<br />

Range of application:<br />

R90 wall and ceiling ducts of flammable pipelines up to<br />

dia. 200 mm (refer to approval notific ation); or sanitary<br />

and <strong>heating</strong> lines, wastewater lines, lines for nonflammable<br />

liquids or gases (not suitable for ventilation<br />

lines)<br />

Processing instructions:<br />

Wall opening: Fix one collar to each side of the wall<br />

ceiling opening: Fix one collar to the underside of the<br />

ceiling<br />

07-410 A/P 07410<br />

Item Unit Designation<br />

number Pieces<br />

003529 10 Nameplate AWM II and III F90<br />

07-410<br />

Fire-protection collar AwM II<br />

For flammable pipes with an outer diameter of up to 125 mm<br />

g Smallest housing dimensions<br />

90° bows can be assembled directly after the wall/<br />

ceiling<br />

Range of application:<br />

R90 wall and ceiling ducts of pipes made of polypropylene,<br />

polyethylene PVc or ABS up to dia. 125 mm<br />

For approved and safe use, the specifications of the<br />

general approval of the building authorities<br />

(Z-19.17-1194) must be observed<br />

Item Unit Designation<br />

number Pieces<br />

001940 2/10 Fire-protection collar AWM III 50/ 52 mm<br />

001941 2/10 Fire-protection collar AWM III 75/ 77 mm<br />

001943 2/10 Fire-protection collar AWM III 110/112 mm<br />

001944 2/10 Fire-protection collar AWM III 125 mm<br />

Processing instructions:<br />

Wall opening: Fix one collar to each side of the wall<br />

ceiling opening: Fix one collar to the underside of the<br />

ceiling<br />

07-410 A/P 07<br />

For approved and safe use, the specifications of the<br />

general approval of the building authorities (Z-19.17-<br />

1651) must be observed<br />

www.<strong>BTI</strong>-GROUP.COM<br />

07<br />

A<br />

459