1006<br />
�����<br />
Fire-protection collar AwM II<br />
For R90 wall and ceiling ducts of flammable pipe lines up to dia. 200 mm; especially for leading through<br />
flammable drainpipe systems<br />
g Smallest housing dimensions<br />
90° bows can be assembled directly after the wall/<br />
ceiling<br />
g Secure structure-borne noise isolation<br />
Insulation up to 4 mm thickness can be led through<br />
the wall/ceiling<br />
g Sloped insertion through the wall is possible<br />
The collar can exceed the outer diameter of the pipe<br />
by up to three times the size<br />
g For core hole drillings, the gap does not need to<br />
be filled for a max. of 5 mm between the pipeline<br />
and the borehole wall<br />
Item Unit Designation<br />
number Pieces<br />
015906 2/10 Fire-protection collar AWM II 50/ 52 mm<br />
014080 2/10 Fire-protection collar AWM II 75/ 77 mm<br />
008327 2/10 Fire-protection collar AWM II 90/ 92 mm<br />
014081 2/10 Fire-protection collar AWM II 110/112 mm<br />
014082 2/10 Fire-protection collar AWM II 125 mm<br />
008326 2/20 Fire-protection collar AWM II 160 mm<br />
008328 2/20 Fire-protection collar AWM II 200 mm<br />
Range of application:<br />
R90 wall and ceiling ducts of flammable pipelines up to<br />
dia. 200 mm (refer to approval notific ation); or sanitary<br />
and <strong>heating</strong> lines, wastewater lines, lines for nonflammable<br />
liquids or gases (not suitable for ventilation<br />
lines)<br />
Processing instructions:<br />
Wall opening: Fix one collar to each side of the wall<br />
ceiling opening: Fix one collar to the underside of the<br />
ceiling<br />
07-410 A/P 07410<br />
Item Unit Designation<br />
number Pieces<br />
003529 10 Nameplate AWM II and III F90<br />
07-410<br />
Fire-protection collar AwM II<br />
For flammable pipes with an outer diameter of up to 125 mm<br />
g Smallest housing dimensions<br />
90° bows can be assembled directly after the wall/<br />
ceiling<br />
Range of application:<br />
R90 wall and ceiling ducts of pipes made of polypropylene,<br />
polyethylene PVc or ABS up to dia. 125 mm<br />
For approved and safe use, the specifications of the<br />
general approval of the building authorities<br />
(Z-19.17-1194) must be observed<br />
Item Unit Designation<br />
number Pieces<br />
001940 2/10 Fire-protection collar AWM III 50/ 52 mm<br />
001941 2/10 Fire-protection collar AWM III 75/ 77 mm<br />
001943 2/10 Fire-protection collar AWM III 110/112 mm<br />
001944 2/10 Fire-protection collar AWM III 125 mm<br />
Processing instructions:<br />
Wall opening: Fix one collar to each side of the wall<br />
ceiling opening: Fix one collar to the underside of the<br />
ceiling<br />
07-410 A/P 07<br />
For approved and safe use, the specifications of the<br />
general approval of the building authorities (Z-19.17-<br />
1651) must be observed<br />
www.<strong>BTI</strong>-GROUP.COM<br />
07<br />
A<br />
459