Sanitation, heating, air-conditioning (PDF / 6,4 MB - BTI
Sanitation, heating, air-conditioning (PDF / 6,4 MB - BTI
Sanitation, heating, air-conditioning (PDF / 6,4 MB - BTI
- TAGS
- sanitation
- heating
- en.bti.de
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
1006<br />
Spacing bracket E25<br />
Wall bracket (readymade)<br />
PSM standard pipe clamp<br />
Square threaded plate<br />
�����<br />
Downspout support fixing for SML downspout supports<br />
The variable adjustment possibilities of the <strong>BTI</strong> downspout support allows building tolerances to be<br />
compensated for, thereby allowing downspouts to be laid without tensioning<br />
Pipe dia. SET content Item<br />
number<br />
100 1 standard pipe clamp with PSM EPDM/SBR DN 108-112 017223<br />
2 spacing brackets E 25<br />
2 wall brackets 35/21/2 Type 250<br />
2 hex screws M10 x 20 a/f 17<br />
2 square thread boards 35 x 30 M10<br />
125 1 standard pipe clamp with PSM EPDM/SBR DN 133-136 017224<br />
2 spacing brackets E 25<br />
2 completed consoles 36/40/2 Type 315<br />
2 hex screws M10 x 20 a/f 17<br />
2 square thread boards 35 x 30 M10<br />
150 1 standard pipe clamp with PSM EPDM/SBR DN 158-163 017225<br />
2 spacing brackets E 25<br />
2 completed consoles 36/40/2 Type 315<br />
2 hex screws M10 x 20 a/f 17<br />
2 square thread boards 35 x 30 M10<br />
200 1 standard pipe clamp with PSM EPDM/SBR DN 209-215 017226<br />
2 spacing brackets E 25<br />
2 completed consoles 45/40/3 Type 315<br />
2 hex screws M10 x 20 a/f 17<br />
2 square thread boards 35 x 30 M10<br />
Load values<br />
Downspout supports<br />
Per. tension<br />
σper. = 160 N/mm 2<br />
max. bending<br />
f = L/150<br />
DN F1 kN F2 kN<br />
100 3.60 0.80<br />
125 2.60 2.20<br />
150 2.60 2.20<br />
200 6.80 3.40<br />
F1<br />
L/2 L/2<br />
L<br />
F2<br />
www.<strong>BTI</strong>-GROUP.COM<br />
07<br />
C<br />
515