09.02.2013 Views

Sanitation, heating, air-conditioning (PDF / 6,4 MB - BTI

Sanitation, heating, air-conditioning (PDF / 6,4 MB - BTI

Sanitation, heating, air-conditioning (PDF / 6,4 MB - BTI

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

1006<br />

�����<br />

isovlies DN/isovlies Plus DN<br />

For <strong>air</strong> and structure-borne insulation and for anti-sweat insulation in HT-, PE-, SML drainpipes.<br />

g Particularly good noise-insulation and reduction<br />

of flow and cracking noises<br />

Tested 4- or 6 mm synthetic noise-insulation mat<br />

g Excellent protection against condensation<br />

The outer skin of the PE foil protects the insulation<br />

material and the pipe from damp, heat bridges are<br />

avoided due to very good thermal conductance,<br />

wastewater lines and parts bordering them are<br />

securely protected against condensation.<br />

Important:<br />

Observe the required thickness of insulation to<br />

prevent condensation!<br />

g Fast and easy to pull over<br />

Even with sockets and bows of HT pipes<br />

g High rate of safety against damage, even when<br />

installed under the plaster<br />

Outer skin resistant to trampling and tear-proof<br />

g Free from materials aggressive to metal<br />

Tested: FMPA V/96 1090 Vo/Gö<br />

welding strip:<br />

g No overlapping<br />

Flush connection of the insulation mat<br />

g No vapor diffusion bridges<br />

completely welded with PE outer skin<br />

Synthetic insulation mat:<br />

g without chemical irritants<br />

g No materials aggressive to metal<br />

Test certificate from the Forschungs- und<br />

Materialprüfanstalt Baden-Württemberg, Germany<br />

PE foil outer skin (silver):<br />

g Clean appearance<br />

g Extremely resistant to trampling and tear-proof<br />

complete connection with the synthetic mat<br />

Technical data<br />

Material: PE-coated polyester mat<br />

Temperature resistance: -70 °c to +115 °c<br />

Reaction to fire * B2 normal flammability<br />

acc. to DIN 4102<br />

* isovlies DN FMPA 16-78226<br />

* isovlies Plus DN FMPA 16-27822a<br />

Insulation thickness of isovlies DN 4 mm<br />

Insulation thickness of Plus DN 6 mm<br />

Noise tested ** Noise-insulation of<br />

wastewater systems,<br />

Fraunhofer Institute for Building Physics<br />

** isovlies DN IBP P-BA 176/1997<br />

* isovlies Plus DN IBP P-BA 237/1998<br />

Thermal conductance *** Test certificate<br />

Tested acc. to DIN 52613 of the Fraunhofer Institute for<br />

(pipe behavior) Building Physics IBP P2-10/1990<br />

*** Tube at 10 °c mean temperature 0.0397 W/mK<br />

*** Strips at 10 °c mean temperature 0.0394 W/mK<br />

Noise-insulation: isovlies DN isovlies Plus DN<br />

Plastic pipe (HT): 25 dB(A) * 21 dB(A) *<br />

Castironpipe (SML): 19 dB(A) * –<br />

* Remaining noise values are disconnected from the sound bridge<br />

compare with the test certificate from the Fraunhofer Institute for construction physics<br />

Please request<br />

proof certificates!<br />

www.<strong>BTI</strong>-GROUP.COM<br />

07<br />

A<br />

431

Hooray! Your file is uploaded and ready to be published.