1006<br />
�����<br />
isovlies DN/isovlies Plus DN<br />
For <strong>air</strong> and structure-borne insulation and for anti-sweat insulation in HT-, PE-, SML drainpipes.<br />
g Particularly good noise-insulation and reduction<br />
of flow and cracking noises<br />
Tested 4- or 6 mm synthetic noise-insulation mat<br />
g Excellent protection against condensation<br />
The outer skin of the PE foil protects the insulation<br />
material and the pipe from damp, heat bridges are<br />
avoided due to very good thermal conductance,<br />
wastewater lines and parts bordering them are<br />
securely protected against condensation.<br />
Important:<br />
Observe the required thickness of insulation to<br />
prevent condensation!<br />
g Fast and easy to pull over<br />
Even with sockets and bows of HT pipes<br />
g High rate of safety against damage, even when<br />
installed under the plaster<br />
Outer skin resistant to trampling and tear-proof<br />
g Free from materials aggressive to metal<br />
Tested: FMPA V/96 1090 Vo/Gö<br />
welding strip:<br />
g No overlapping<br />
Flush connection of the insulation mat<br />
g No vapor diffusion bridges<br />
completely welded with PE outer skin<br />
Synthetic insulation mat:<br />
g without chemical irritants<br />
g No materials aggressive to metal<br />
Test certificate from the Forschungs- und<br />
Materialprüfanstalt Baden-Württemberg, Germany<br />
PE foil outer skin (silver):<br />
g Clean appearance<br />
g Extremely resistant to trampling and tear-proof<br />
complete connection with the synthetic mat<br />
Technical data<br />
Material: PE-coated polyester mat<br />
Temperature resistance: -70 °c to +115 °c<br />
Reaction to fire * B2 normal flammability<br />
acc. to DIN 4102<br />
* isovlies DN FMPA 16-78226<br />
* isovlies Plus DN FMPA 16-27822a<br />
Insulation thickness of isovlies DN 4 mm<br />
Insulation thickness of Plus DN 6 mm<br />
Noise tested ** Noise-insulation of<br />
wastewater systems,<br />
Fraunhofer Institute for Building Physics<br />
** isovlies DN IBP P-BA 176/1997<br />
* isovlies Plus DN IBP P-BA 237/1998<br />
Thermal conductance *** Test certificate<br />
Tested acc. to DIN 52613 of the Fraunhofer Institute for<br />
(pipe behavior) Building Physics IBP P2-10/1990<br />
*** Tube at 10 °c mean temperature 0.0397 W/mK<br />
*** Strips at 10 °c mean temperature 0.0394 W/mK<br />
Noise-insulation: isovlies DN isovlies Plus DN<br />
Plastic pipe (HT): 25 dB(A) * 21 dB(A) *<br />
Castironpipe (SML): 19 dB(A) * –<br />
* Remaining noise values are disconnected from the sound bridge<br />
compare with the test certificate from the Fraunhofer Institute for construction physics<br />
Please request<br />
proof certificates!<br />
www.<strong>BTI</strong>-GROUP.COM<br />
07<br />
A<br />
431