www.<strong>BTI</strong>-GROUP.COM<br />

07<br />

A<br />

Technical data<br />

Swelling temperature 150 °c<br />

Swelling volume up to 5 times<br />

Resistant against weak acids and alkalines,<br />

technical fuels, oils<br />

damp and water<br />

Dimension 250 x 470 mm<br />

Vario-Sol kit<br />

Particularly suitable for use in core hole drillings<br />

≤ 15 mm<br />

Processing instructions:<br />

Fill the remaining cross-section in the entire ceiling<br />

and-/wall thickness with Vario-Sol kit,<br />

max. gap width: 15 mm, min. processing depth:<br />

�����<br />

Vario-Sol<br />

Vario-Sol is a building material that foams up in case of a fire and is designed for F90 wall and ceiling ducts of<br />

flammable and non-flammable pipes<br />

Legal regulations such as the ordinance for prototype<br />

buildings, the German “Landesbauordnung” (LBO),<br />

the prototype regulations on fire requirements at line<br />

and pipe systems (MLAR) contain three main basic<br />

requirements for the design of the building:<br />

g Prevention of fire spreading<br />

g Prevention of the spreading of smoke gases<br />

(even cold smoke)<br />

g Prevention of the spreading of noise<br />

Vario-Sol was developed for pipe ducts designed for<br />

practical conditions that take these requirements into<br />

consideration.<br />

g For F90 wall and ceiling ducts of flammable and<br />

non-flammable pipes<br />

General approval from the building authorities:<br />

Z-19.11- 1379 (for building materials that foam up<br />

in case of fire)<br />

g Flexible<br />

can be assembled on sockets and casing fittings<br />

g Odor- and smoke tight against cold smoke<br />

Due to a ribbed profile and gluing of the end pieces<br />

with A2 aluminum tape<br />

g In case of a fire, foams up to five times its size<br />

from a temperature of approx. 150 °C<br />

joints and small openings that may result from<br />

Vario-Sol acc. to MLAR<br />

a ≥ 50 mm *<br />

b ≥ 60 mm<br />

c = 5 mm<br />

d ≈ 30 mm<br />

e ≥ 0 mm<br />

f = 30 mm *<br />

* continuative insulation non-flammable<br />

Vario-Sol board<br />

Particularly suitable for use for recesses in walls and ceilings<br />

Processing instructions:<br />

� cut Vario-Sol to the length of the pipe circumference<br />

� Lay Vario-Sol around the pipe and fix with tape at the longitudinal joint<br />

� Glue both ends odor-tight and to protect against cold smoke with A2 tape<br />

thermal movement of pipelines are closed safely; the<br />

transmission of fire and smoke is prevented<br />

g Permanently elastic material with ribbed profile<br />

Transmission of noise to adjacent masonry is<br />

effectively reduced<br />

Range of application:<br />

F90 fire-protection solution for water, <strong>heating</strong> and<br />

drainpipes; approved according to DIN 4102 and the<br />

prototype pipe system regulations (MLAR) for nonflammable<br />

pipes (except aluminum and glass) up to<br />

160 mm; flammable pipes ≤ 32 mm pipe outer dia.<br />

Processing instructions:<br />

Water-soluble in non-hardened state; protect from<br />

immediate weather influences, particularly driving rain<br />

and the change from frost to condensation<br />

Item Unit Designation<br />

number Pieces<br />

� � �<br />

010485 25 Vario-Sol board<br />

010754 12 Vario-Sol kit 310 ml<br />

011636 10 Designation plate for Vario-Sol<br />

07-413 A/P/T 07413AA<br />

g with just one product, Vario-Sol covers all pipe diameters as the single cuts can be cut individually from the<br />

complete board<br />

Vario-Sol kit Installation example<br />

1 = SML drainpipe DN 100 dia. 110 mm<br />

2 = non-flammable pipe dia. 28 mm<br />

3 = non-flammable pipe dia. 28 mm<br />

456 4 – 5 cm (on both sides)<br />

� Fill the space between the Vario-Sol board and the wall/ceiling with cement mortar or concrete<br />