158 Industrial Hydraulics<br />

yy<br />

Specifications<br />

PCB Format (100 x 160 x approx. 35) mm (W x L x H), Europe <strong>for</strong>mat with front plate<br />

(7 modular spacings)<br />

Plug connection Plug to DIN 41 612-F32<br />

Ambient temperature 0 °C ... +70 °C; storage temperature min. –20 °C, max. +70 °C<br />

Power supply UB to z2–b2 24 V DC nominal<br />

battery voltage 21 ... 40 V<br />

Rectified AC voltage Ueff = 21 ... 28 V<br />

(single-phase, full-wave rectification)<br />

Smoothing capacitor, 4700 µF/63 V DC, only required if UB ripple > 10%<br />

connected separately to b4, z4<br />

Current rating 250 mA max.<br />

Setpoint signal Q b20: 0 ... ±10 V<br />

z20: 0 V<br />

Difference amplifier<br />

(Ri = 100 kΩ)<br />

Setpoint signal pdiff<br />

z10: 0 ... ±10 V<br />

z12: 0 V � Difference amplifier<br />

Feedback signal from<br />

pressure sensor<br />

A b26: 0 ... +10 V<br />

b28: 0 V � Difference amplifier<br />

b24:<br />

b30:<br />

4 ... 20 mA<br />

B b16: 0 ... +10 V<br />

b18: 0 V � Difference amplifier<br />

z14:<br />

z30:<br />

4 ... 20 mA<br />

Power supply <strong>for</strong> pressure sensors z6: +15 V, max. 100 mA<br />

z8: –15 V, max. 100 mA<br />

Pressure controller OFF b10: 6 ... 40 V DC<br />

External controller signal z24: 24 V/0.1 A max., if controller not operative<br />

Signal source External potentiometer 10 kΩ<br />

±10 V supply from b32, z32 (10 mA) or external signal source<br />

Monitor signal Ffeedback<br />

z16: ±10 V<br />

Error, pressure sensor b22: no fault: +UK; max. 100 mA<br />

(open circuit in signal lines) b22: fault: 0 V<br />

b22: LED “Ramp off A” and<br />

“Ramp off B” flash<br />

Ramp times min. 350 ms (1)<br />

max. 5.6 s (16)<br />

16 stages<br />

� 350 ms/stage<br />

Ramp OFF A z22: 6 ... 40 V DC<br />

B z26: 6 ... 40 V DC<br />

Surface area adaptation, cylinder min. 1:1 (1)<br />

max. 1:4 (16) � 16 stages<br />

LED-displays red: fault UB<br />

red: ramp OFF A<br />

red: ramp OFF B<br />

green/yellow: green, controller operative<br />

yellow, controller not operative<br />

off, controller OFF<br />

Important! Connect power zero b2 and control zero b12, b14 or z28 separately to central gro<strong>und</strong> (neutral point).<br />