5<br />
158 Industrial Hydraulics<br />
yy<br />
Specifications<br />
PCB Format (100 x 160 x approx. 35) mm (W x L x H), Europe <strong>for</strong>mat with front plate<br />
(7 modular spacings)<br />
Plug connection Plug to DIN 41 612-F32<br />
Ambient temperature 0 °C ... +70 °C; storage temperature min. –20 °C, max. +70 °C<br />
Power supply UB to z2–b2 24 V DC nominal<br />
battery voltage 21 ... 40 V<br />
Rectified AC voltage Ueff = 21 ... 28 V<br />
(single-phase, full-wave rectification)<br />
Smoothing capacitor, 4700 µF/63 V DC, only required if UB ripple > 10%<br />
connected separately to b4, z4<br />
Current rating 250 mA max.<br />
Setpoint signal Q b20: 0 ... ±10 V<br />
z20: 0 V<br />
Difference amplifier<br />
(Ri = 100 kΩ)<br />
Setpoint signal pdiff<br />
z10: 0 ... ±10 V<br />
z12: 0 V � Difference amplifier<br />
Feedback signal from<br />
pressure sensor<br />
A b26: 0 ... +10 V<br />
b28: 0 V � Difference amplifier<br />
b24:<br />
b30:<br />
4 ... 20 mA<br />
B b16: 0 ... +10 V<br />
b18: 0 V � Difference amplifier<br />
z14:<br />
z30:<br />
4 ... 20 mA<br />
Power supply <strong>for</strong> pressure sensors z6: +15 V, max. 100 mA<br />
z8: –15 V, max. 100 mA<br />
Pressure controller OFF b10: 6 ... 40 V DC<br />
External controller signal z24: 24 V/0.1 A max., if controller not operative<br />
Signal source External potentiometer 10 kΩ<br />
±10 V supply from b32, z32 (10 mA) or external signal source<br />
Monitor signal Ffeedback<br />
z16: ±10 V<br />
Error, pressure sensor b22: no fault: +UK; max. 100 mA<br />
(open circuit in signal lines) b22: fault: 0 V<br />
b22: LED “Ramp off A” and<br />
“Ramp off B” flash<br />
Ramp times min. 350 ms (1)<br />
max. 5.6 s (16)<br />
16 stages<br />
� 350 ms/stage<br />
Ramp OFF A z22: 6 ... 40 V DC<br />
B z26: 6 ... 40 V DC<br />
Surface area adaptation, cylinder min. 1:1 (1)<br />
max. 1:4 (16) � 16 stages<br />
LED-displays red: fault UB<br />
red: ramp OFF A<br />
red: ramp OFF B<br />
green/yellow: green, controller operative<br />
yellow, controller not operative<br />
off, controller OFF<br />
Important! Connect power zero b2 and control zero b12, b14 or z28 separately to central gro<strong>und</strong> (neutral point).<br />
➤<br />
➤<br />
�