USER INSTRUCTIONS - ENGLISH<br />
7.3 Mounting Winches/SRL’s with<br />
Retrieval to DH-1, DH-2 and DH-3 Mast<br />
7.3.1.2 Combination Applications<br />
To ensure that your winch/SRL doesn’t encounter interference from proper operation, refer to the recommended<br />
mounting positions below.<br />
A typical application includes a MightEvac (retractable), which should be mounted to the front of the mast, and<br />
either a 100/200 Series Winch, a ManHandler, or a Basic Winch, which are mounted to the back. Other mounting<br />
locations are possible; it is up to the user to determine alternative applications and to make sure there is no<br />
interference.<br />
NOTE: Make sure rescue handle rotates 360° with no interference.<br />
WARNING<br />
<strong>The</strong>se are recommended<br />
starting locations. Others are<br />
possible. It’s up to the user<br />
to determine those locations<br />
without interference.<br />
0<br />
100/ 0/<br />
2000<br />
Series<br />
100/200 Series Winch<br />
MightEvac<br />
Position 1<br />
Position 2<br />
D H-19/D H-19-A P-8<br />
Mount to back<br />
at position #5<br />
Example:<br />
DH-100 Winch & MightEvac<br />
D H-19-MILL E R<br />
Mount to front<br />
at position #3<br />
Position 3<br />
Position 4<br />
Position 5<br />
Position 6<br />
ManHandler<br />
D H-1 9- MILLE R<br />
Mount to back<br />
at position #5<br />
Position 7<br />
Basic Winches<br />
Mount to back<br />
at position #5<br />
D H-19/D H-19-A P-8<br />
Front<br />
Side<br />
Back<br />
Side<br />
27