12.07.2015 Views

Trumatic C 6002 EH

Trumatic C 6002 EH

Trumatic C 6002 EH

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Trumatic</strong> C <strong>6002</strong> <strong>EH</strong>1 Control panel2 Power selector switch3 Time switch ZUC 2 (Accessories)4 Room temperature sensor5 Cold water connection6 Hot water connection7 Gas connection8 Hot air outlets9 Circulating air return line10 Waste gas discharge11 Combustion air infeed12 Electronic control unit13 Power electronics14 Overheating switch 230 V15 Water container (12 litres)16 Igniter17 Burner18 Heat exchanger19 Overheating protector20 Heating elements 230 V21 Electrical safety/drainage valveFunction descriptionThe <strong>Trumatic</strong> C <strong>6002</strong> <strong>EH</strong>combination device combinesthe benefits of a stationaryelectric heater withthe considerable heatingpower of an independentgas heater.Irrespective of whether youjust wish to have hot waterin summer mode or justheat or heat and hot waterin winter mode, 3 powerselection options areavailable:– Gas only (propane/butane)for independent operation– Electricity only (230 V)for stationary operation on acamping site– or Gas and Electricity(simultaneously).Summer mode(hot water only)Either gas operation or 230 Velectricity operation is usedfor preparing hot water. Thewater temperature can be setto 40°C or 60°C.For gas operation the deviceautomatically selectsthe smallest burner settingat 2000 W. The water temperatureis controlled by theautomatic controller, whichis powered by 12 V from thevehicle battery.Depending on the fuse protectionat the camping site,power of 900 W (3.9 A) or1800 W (7.8 A) can be manuallyselected for electricaloperation.Mixed operation(simultaneous gas andelectricity) is not possible.With this setting the deviceautomatically selects electricaloperation at the selectedpower of 900 W or 1800 W.The gas burner is not enabled.Winter mode(heat and hot water)All 3 energy selection optionscan be used for winter deployment.With gas operation thedevice automatically selectsthe burner setting that is required(2000 W, 4000 W orup to 6000 W) depending onthe output requirement (calculatedfrom difference betweenselected temperatureand current room temperature).The circulation fan thatis needed to distribute thewarm air and the automaticroom temperature and safetymonitoring controller arepowered by the vehiclebattery (12 V).Depending on the fuse protectionat the camping site,power of 900 W (3.9 A) or1800 W (7.8 A) can be manuallypreselected for electricaloperation.If the power requirementis higher (e.g.heating up or low outsidetemperatures) gas operationor mixed operation must beselected, since the 230 Velectrical heater is only a secondaryheater with maximumheating power of 1800 W.In mixed operation the fullheating power of 7800 W(6000 W gas + 1800 Welectricity) is available. Thiscombination guaranteesrapid heat-up times, even atextremely low outside temperatures.The heating powerthat is required (calculatedfrom difference betweenselected temperature andcurrent room temperature)is selected automatically bythe unit. If the power requirementis low (e.g. for maintainingroom temperature),230 V electrical operation isgiven priority. The gas burneris not enabled until the powerrequirement is higher, and isthe first to switch off duringheat-up operations.Heating is alwayspossible in all operatingmodes (gas, electricand mixed operation) withoutrestrictions, with orwithout water.9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!