15.2 Storage<br />

General storage conditions<br />

Dry location (maximum of 75% relative humidity)<br />

Dust-free<br />

Even ambient temperature<br />

Wire rope storage conditions:<br />

Lightly greased<br />

Avoid contact with chemicals (e.g. battery acid).<br />

Store without any mechanical crushing, pressure or tensile<br />

stress.<br />

16 Maintenance work<br />

16.1 Authorized maintenance personnel<br />

DANGER!<br />

Risk of falling! Risk of being injured by falling objects!<br />

Danger of death due to incorrectly carried out maintenance or<br />

service work!<br />

Maintenance and service work which requires the product to<br />

be opened may only be performed by the following authorized<br />

parties:<br />

– The Greifzug Hebezeugbau <strong>GmbH</strong><br />

– Lifting equipment service companies authorized by<br />

Greifzug Hebezeugbau <strong>GmbH</strong><br />

– Service personnel trained and certified by Greifzug Hebezeugbau<br />

<strong>GmbH</strong><br />

16.2 Mandatory inspections<br />

A written certificate is required for the annual safety inspection<br />

and any exceptional tests. The inspections must be recorded in<br />

the logbook included with delivery.<br />

Prior to every use<br />

Always check to ensure that the device is in an orderly working<br />

condition before use, see '10.4 Commissioning' on page 10.<br />

Annual safety inspection<br />

The safety inspection must be carried out annually.<br />

The safety inspection may only be undertaken by authorised<br />

maintenance personnel, see '16.1 Authorized maintenance personnel'<br />

on page 15. Depending on the usage conditions (e.g.<br />

operation in an extremely dirty environment), an intermediate<br />

inspection may be necessary.<br />

We recommend that the system is tested in our factory by<br />

Greifzug Hebezeugbau <strong>GmbH</strong>.<br />

Installation and operating manual<br />

Contact Greifzug Hebezeugbau <strong>GmbH</strong> or your supplier with<br />

regards to this test.<br />

Exceptional tests<br />

The independent secondary brake must be inspected by<br />

Greifzug Hebezeugbau <strong>GmbH</strong> or an authorised hoisting gear<br />

workshop.<br />

See '12.3 Measures to be taken after a problem or an emergency-stop'<br />

on page 13.<br />

16.3 Care and maintenance<br />

Interval Work Implementation<br />

Weekly – Lubricate the safety rope<br />

1 x annually<br />

/<br />

every 250<br />

operating<br />

hours of<br />

the hoist<br />

Whenever<br />

necessary<br />

Rope<br />

– Clean the independent<br />

secondary brake housing<br />

– Inspect for clamping jaw<br />

wear<br />

– Check for pressure / drive<br />

roller wear<br />

– Replace the clamping jaws<br />

– Replace the pressure / drive<br />

rollers<br />

Operating personnel<br />

Authorised maintenance<br />

personnel<br />

Authorised maintenance<br />

personnel<br />

– Replace the safety rope Trained person nominated<br />

by the operator<br />

DANGER!<br />

Risk of injury through stabs and cuts!<br />

Broken wires in the wire rope can result in protruding wires!<br />

Protruding wires can cut or stab through safety gloves!<br />

– Wear suitable leather protective gloves when working<br />

with wire ropes.<br />

– Never let the wire rope run through your hands!<br />

Cleaning<br />

Brush the dirt off soiled ropes when dry if necessary. Re-lubricate<br />

as necessary.<br />

G905.5 - 02/2011 EN-15