Section F- Supply <strong>Air</strong> Section<br />
Section Mounted Controls<br />
SCB- Split Junction Box (Code 05= F)- TB25,TB27,TB28,PB10,PB9,PB20,PB19<br />
Across- The- Line Start (Code 05= AL)<br />
TB28 TB27 TB25<br />
PB 19 PB 20 PB 9 PB 10<br />
Motor HP<br />
2 - 25 30 40, 50 60 - 75<br />
Sch. Part Part<br />
Sym. Description<br />
Terminal Blocks<br />
Number<br />
TB25 Terminal Block- SCB 015998124 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1<br />
TB27 Terminal Block- SCB 015998130 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1<br />
TB281 Terminal Block- SCB 015998124 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1<br />
PB10 Power Block- Supply Fan<br />
95A, 600V, 3P 030372707 1 1 1 1 1 1 1 1 1 1 1 1 1 1<br />
175A, 600V, 3P 030372710 1 1<br />
PB9 Power Block- Supply Fan<br />
95A, 600V, 3P 030372707 1 1 1<br />
PB20 Power Block- Return Fan<br />
95A, 600V, 3P 030372707 1 1 1 1 1 1 1 1 1 1 1 1<br />
PB19 Power Block- Return Fan<br />
95A, 600V, 3P<br />
Part Winding Start (Code 05= PP)<br />
030372707 1<br />
2<br />
Motor HP<br />
2 - 25 30 40, 50 60 - 75<br />
Sch. Part Part<br />
Sym. Description<br />
Terminal Blocks<br />
Number<br />
TB25 Terminal Block- SCB 015998124 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1<br />
TB27 Terminal Block- SCB 015998130 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1<br />
TB281 Terminal Block- SCB 015998124 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1<br />
PB10 Power Block- Supply Fan<br />
95A, 600V, 3P 030372707 1 1 1 1 1 1 1 1 1 1 1 1 1 1<br />
175A, 600V, 3P 030372710 1 1<br />
PB9 Power Block- Supply Fan<br />
95A, 600V, 3P 030372707 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1<br />
PB20 Power Block- Return Fan<br />
95A, 600V, 3P 030372707 1 1 1 1 1 1 1 1 1 1 1 1<br />
PB19 Power Block- Return Fan<br />
95A, 600V, 3P 030372707 1 1 1 1 1 1 1 1 1 1 1 1<br />
1 Only used when the unit has a supply fan inverter, VIV, or an Economizer with a Power Closure Exhaust Damper.<br />
2 Part Winding Fans are rare (and no longer offered).<br />
<strong>RoofPak</strong> Singlezone; <strong>RAH</strong> <strong>077</strong> “C” Rev. Q 07/12 <strong>RPL</strong> 700008300 / Page 107<br />
208V<br />
208V<br />
230V<br />
230V<br />
460V<br />
460V<br />
575V<br />
575V<br />
208V<br />
208V<br />
230V<br />
230V<br />
460V<br />
460V<br />
575V<br />
575V<br />
208V<br />
208V<br />
230V<br />
230V<br />
460V<br />
460V<br />
575V<br />
575V<br />
208V<br />
208V<br />
230V<br />
230V<br />
460V<br />
460V<br />
575V<br />
575V