Section N- Main Control Box<br />

MicroTech II or No Controls Control Panel— 3/05 and later*<br />

Components, Continued<br />

* Code 08= D. Between 10/04 & 3/05 either this control panel or the original MicroTech II control panel (Code 08= P) could be installed.<br />

Check the GO or visually inspect the unit to verify which panel is installed. If built between 10/06 and 12/06 contact Daikin McQuay Parts.<br />

Sch. Part Part<br />

Sym. Description<br />

Relays 3/05 to 10/06<br />

Number Qty.<br />

1<br />

R20 Relay- Steam or Hot Water Heat Code 04= S or W<br />

Units with Controller Code 12= _D, _S 349934901 1<br />

Units with No Controller Code 12= YM 349934704 1<br />

Relay- Electric Heat Code 04= E 349934701 1<br />

Relay- Gas Heat 2 Code 04= A<br />

Units with Controller Code 12= _D, _S<br />

Hi Turn Down Burner Code 34 (5th digit)= H,T,U 016508002 1<br />

Modulating Burner Code 34(5th digit)= E,R,S 026213000 1<br />

Units w/No Controller & Gas Actuator Code 12= YC<br />

Hi Turn Down Burner Code 34 (5th digit)= H,T,U 073340001 1<br />

Modulating Burner Code 34(5th digit)= E,R,S 027400700 1<br />

Units w/No Controller & Float Control Code 12= YM<br />

Hi Turn Down Burner Code 34 (5th digit)= H,T,U 019643000 1<br />

Modulating Burner Code 34(5th digit)= E,R,S 027400700 1<br />

R24 Relay- Gas Heat Alarm Code 04= A 349934704 1<br />

R25 Relay- Gas Heat, Start Supply Fan Inverter Code 14= 1, 2,3,5,6,7 349934704 1<br />

R26 Relay- Iso Damper- Open/Close 349934901 1<br />

R28 Relay- Isolation Damper Safety 349934701 1<br />

R30 Relay- Cool Valve w/ Face Bypass 349934704 1<br />

R45 Relay- UV Lights 349934701 1<br />

R46 Relay- Inverter, Supply Fan increase/decrease Code 14= 1-3,5-7 112033501 1<br />

R48 Relay- Inverter, Return Fan increase/decrease Code 14= 2,4,5,7-9 112033501 1<br />

R61 Relay- Discharge <strong>Air</strong> Smoke Detector 349934701 1<br />

R63 Relay- Specials 349934901 1<br />

R66 Relay- Return <strong>Air</strong> Smoke Detector Code 16= 1 or 3 349934701 1<br />

R67 Relay- Supply Fan Enable<br />

No Controller Code 12= YM, YC 349934704 1<br />

With Controller Code 12= _D, _S 349934701 1<br />

R68 Relay- Return Fan Enable<br />

No Controller Code 12= YM, YC 349934704 1<br />

With Controller Code 12= _D, _S 349934701 1<br />

R69 Relay- Inverter Bypass VAV Interlock Code 14= 1-9 349934704 1<br />

R70 Relay- Specials 349934701 1<br />

1 There was a change in many of the Main Box components at the end of 2006. The majority of the component changes occurred<br />

in the power panel. The only components that changed in the control panel were several of the relays. See the following<br />

page for relays used in units built 1/07 & later. If the unit was built between 10/06 & 12/06 contact Daikin McQuay Parts to<br />

verify which controls are installed.<br />

2 All R20 options are detailed here but for units with gas heat, the R20 is located in the gas heat control box (see section G).<br />

<strong>RoofPak</strong> Singlezone; <strong>RAH</strong> <strong>077</strong> “C” Rev. Q 07/12 <strong>RPL</strong> 700008300 / Page 198