Section N- Main Control Box<br />

Power Panel 3/05 to 10/06*<br />

Components<br />

* Code 08= D. Between 10/04 & 3/05 either this control panel or the original MicroTech II control panel (Code 08= P) could be installed.<br />

Check the GO or visually inspect the unit to verify which panel is installed. If built between 10/06 and 12/06 contact Daikin McQuay Parts.<br />

Sch. Part Part Voltage<br />

Sym. Description<br />

Terminal Blocks<br />

Number 208V 230V 460V 575V<br />

TB2, 3, 7 Terminal Block- Field<br />

Transformer- Main<br />

349930603 1 1 1 1<br />

T1 Transformer- Main Control<br />

Electric, Hydronic, or No Heat C04= E,S,W,Y<br />

Units without UV Lights & No Controls (C12= YM) 038253963 1<br />

Units without UV Lights & No Controls (C12= YM) 038253988 1 1 1<br />

Units without UV Lights w/ MicroTech 038253966 1<br />

Units without UV Lights w/ MicroTech 038253991 1 1 1<br />

Units with UV Lights Code 17 (2nd digit)= 1-8 038253967 1<br />

Units with UV Lights Code 17 (2nd digit)= 1-8 038253992 1 1 1<br />

Gas Heat C04= A<br />

Units without UV Lights 038253967 1<br />

Units without UV Lights 038253992 1 1 1<br />

Units with UV Lights Code 17 (2nd digit)= 1-8 038253968 1<br />

Units with UV Lights Code 17 (2nd digit)= 1-8 038253959 1 1<br />

Units with UV Lights<br />

Fuses- T1<br />

Code 17 (2nd digit)= 1-8 038253993 1<br />

2<br />

F1.A,B Fuse- T1 Transformer, Primary<br />

Electric, Hydronic, or No Heat C04= E,S,W,Y<br />

Units without UV Lights & No Controls (C12= YM) 349937125 2<br />

Units without UV Lights & No Controls (C12= YM) 349937124 2 2<br />

Units without UV Lights & No Controls (C12= YM) 349937123 2<br />

Units without UV Lights w/ MicroTech (C12= 1-5M) 349937133 2<br />

Units without UV Lights w/ MicroTech (C12= 1-5M) 349937135 2<br />

Units without UV Lights w/ MicroTech (C12= 1-5M) 349937129 2<br />

Units without UV Lights w/ MicroTech (C12= 1-5M) 349937127 2<br />

Units with UV Lights Code 17 (2nd digit)= 1-8 349937136 2 2<br />

Units with UV Lights Code 17 (2nd digit)= 1-8 349937132 2<br />

Units with UV Lights Code 17 (2nd digit)= 1-8 349937130 2<br />

Gas Heat C04= A<br />

Units without UV Lights 349937136 2 2<br />

Units without UV Lights 349937132 2<br />

Units without UV Lights 349937130 2<br />

Units with UV Lights Code 17 (2nd digit)= 1-8 349937137 2<br />

Units with UV Lights Code 17 (2nd digit)= 1-8 349937133 2 2<br />

Units with UV Lights Code 17 (2nd digit)= 1-8 349937132 2<br />

F1.C Fuse- T1 Transformer ,Secondary 349937035 3 Fuse- Gas <strong>Blow</strong>er Motor<br />

1 1 1 1<br />

F3 Fuse- Burner <strong>Blow</strong>er Motor Code 04= A<br />

Fuse Block 023780223 1 1 1 1<br />

Fuse 200- 1000 mbh furnace 349937035 1 1 1 1<br />

Fuse 1100- 2000 mbh furnace 349937036 1 1 1 1<br />

Fuse Cover 349938207 1 1 1 1<br />

1 Varies depending on unit options. Part number is for one individual section. Ground block is p/n 349930604.<br />

2 All Fuses for the T-1 transformer use a fuse cover/puller p/n 349938207.<br />

3 When a unit has No Gas Heat (C04= E,S,W,Y), No Controls (C12= YM) and No UV Lights, the F1C fuse is p/n 349937129.<br />

<strong>RoofPak</strong> Singlezone; <strong>RAH</strong> <strong>077</strong> “C” Rev. Q 07/12 <strong>RPL</strong> 700008300 / Page 205