RPL: RAH, Size 077, Vintage C, RoofPak Draw Thru / Blow Thru Air ...
RPL: RAH, Size 077, Vintage C, RoofPak Draw Thru / Blow Thru Air ...
RPL: RAH, Size 077, Vintage C, RoofPak Draw Thru / Blow Thru Air ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Section N- Main Control Box<br />
Power Panel— Until 3/05<br />
Fan Motor Contactors, Overloads and Fusing<br />
Components, Continued<br />
10 Horsepower Supply and/or Return Fan Motor- Code 22 or 32= L<br />
Sch. Part Part Voltage<br />
Sym. Description Number 208V 230V 380V 460V 575V<br />
Contactors<br />
M10,20 Contactor- Supply (M10), Return (M20) Fan Motor 027514403 1<br />
Contactor- Supply (M10), Return (M20) Fan Motor 027514402 1<br />
Contactor- Supply (M10), Return (M20) Fan Motor 027514401 1 1 1<br />
Fuse Block and Fuses<br />
FB10,20 Fuse Block- Supply (FB10), Return (FB20) Fan Motor 023780209 1 1<br />
Fuse Block- Supply (FB10), Return (FB20) Fan Motor 023780205 1 1 1<br />
Fuse- FB10 or FB20 025860513 3<br />
Fuse- FB10 or FB20 025860511 3<br />
Fuse- FB10 or FB20 025860407 3 3<br />
Fuse- FB10 or FB20 025860406 3<br />
Overloads and Heaters<br />
OL10,20 Overload- Supply (OL10), Return (OL20) Fan Motor<br />
Until 1/98 030189300 1 1<br />
Until 1/98 030189200 1 1 1<br />
1/98 and later 059990101 1 1 1 1 1<br />
Overload Heater- OL10 or OL20<br />
Standard Efficiency Motor (C22/32= _AY or _GY) 022773400 1 1<br />
Standard Efficiency Motor (C22/32= _AY or _GY) 025070600 1 1<br />
Standard Efficiency Motor (C22/32= _AY or _GY) 022614200 1<br />
High or Prem.Eff. Motor (C22/32= _EY,_FY,_JY,_KY) 1<br />
1/98 and later 059990614 1<br />
1/98 and later 059990613 1<br />
1/98 and later 059990611 1 1 1<br />
LR10,20 Line Reactors 2<br />
NOTE: Quantities Listed are PER motor.<br />
1 For High Efficiency motors used on units built prior to 1/98, see the Overload Heater Chart at the end of this section (located on the<br />
page following the 50HP motors).<br />
2 When the unit has an inverter with bypass (C14= 1, 2, 3, 4, 5, 8) the line reactors are located in the bypass box. When there is no inverter<br />
bypass box the Line Reactors are located in the Main Control Power Panel. The Line Reactor part numbers are listed in Section F.<br />
<strong>RoofPak</strong> Singlezone; <strong>RAH</strong> <strong>077</strong> “C” Rev. Q 07/12 <strong>RPL</strong> 700008300 / Page 178