Section F- Supply <strong>Air</strong> Section<br />

Inverters & Inverter Bypass Control Box<br />

Until 3/05 (Code 8= P)**<br />

Motor HP 30 - 75 (Code 22 or Code 32= Q, R, S, T or U)<br />

Inverters may be located in a separate section (Code 14= 1, 2 or 4, only inverters WITH bypass may be installed in a separate section), or the<br />

Supply <strong>Air</strong> Section (Code 14= 3, 5, 6, 7, 8 or 9). The inverter and bypass controls are the same regardless of the installation location, although<br />

the sheet metal components differ. The diagrams shown below apply to either a return air or supply air inverter (both may be installed if code 14=<br />

5). Even if Code 14= 8 or 9— where only a return air fan inverter is called for— the inverter and bypass controls are still installed in the Supply<br />

<strong>Air</strong> Section.<br />

** If unit was built between 10/04 and 3/05 visual inspection is required to confirm installed components.<br />

40<br />

50<br />

Supply <strong>Air</strong> or Return <strong>Air</strong> Fan<br />

Inverter w/ Bypass Control Box.<br />

(Code 14= 3, 5, 8)<br />

M30A/M30B (Supply)<br />

M40A/M40B (Return)<br />

60<br />

OL10 (Supply)<br />

OL20 (Return)<br />

61A 61<br />

Ref Sch. Part Part<br />

No. Sym. Description Number<br />

40 AFD10,20 Inverter 11 pages after next<br />

Motor Horsepower<br />

30 40 50 60 75<br />

50 Gasket 055940207 1 1 1 1 1 1 1 1 1 1<br />

60 M30AB Contactor 066814304 1 1<br />

M40AB 066814306 1 1<br />

066814307 1 1 1<br />

<strong>RoofPak</strong> Singlezone; <strong>RAH</strong> <strong>077</strong> “C” Rev. Q 07/12 <strong>RPL</strong> 700008300 / Page 88<br />

62<br />

Bypass Controls<br />

Detail<br />

208V<br />

230V<br />

PB10 (Supply)<br />

PB20 (Return)<br />

460V<br />

575V<br />

208V<br />

230V<br />

OR<br />

460V<br />

M10 (Supply)<br />

M20 (Return)<br />

575V<br />

40<br />

Supply <strong>Air</strong> and Return <strong>Air</strong> Fan<br />

Inverter without Bypass.<br />

(Code 14= 7)<br />

208V<br />

40<br />

Supply <strong>Air</strong> or Return <strong>Air</strong> Fan<br />

Inverter without Bypass.<br />

(Code 14= 6, 7, 9)<br />

066814308 1 1 1 1 1 1<br />

61 OL10, 20 Overload<br />

1<br />

61A Heater- OL 1<br />

62 PB10,20 Power Block 030372715 1 1 1 1 1 1 1 1 1 1 1 1 1 1<br />

M10, 20 Contactor 2<br />

1 For part numbers for the OL10 or OL20 and associated heater see “Section N- Main Control Box Power Panel<br />

Until 3/05”.<br />

2 The inverter bypass box originally had a contactor (M10 or M20) installed. This was replaced with the Power Block.<br />

If a contactor is needed see “Section N- Main Control Box Power Panel Until 3/05” for part number(s).<br />

230V<br />

460V<br />

575V<br />

460V<br />

575V<br />

460V<br />

575V